Distribution panel connection
It is recommended that your product is wired through
your vessel’s distribution panel via a thermal breaker
or fuse.
D13017-1
2
3
1
4
5
6
7
1.
Vessel power supply positive (+)
2.
In-line fuse (your product may contain a fuse
already built in to the power cable.)
3.
Product power cable
4.
Vessel power supply negative (-)
5.
* Drain wire
6.
Vessel distribution panel
7.
* Vessel RF ground point connection
Note:
* Only applicable to products that include a
drain wire on the product’s power cable.
Thermal breaker rating
5 A (if only connecting one device)
Battery connection with RF ground
If your vessel does not have a distribution panel then
your product may be wired directly to the battery with
the drain wire connected to the vessel’s RF ground
point.
D13018-1
2
4
5
1
3
6
7
1.
Vessel power supply positive (+)
2.
Vessel power supply negative (-)
3.
In-line fuse (If your products power cable does
not have a built in fuse then an in-line fuse
should be fitted.)
4.
* Drain wire
5.
Product power cable
6.
Vessel battery
7.
* Vessel RF ground point connection
Note:
* Only applicable to products that include a
drain wire on the product’s power cable.
Battery connection with no RF ground
If your vessel does not have a distribution panel
or an RF ground point then your product may be
wired directly to the battery with the drain wire also
connected to the battery’s negative terminal.
D13019-1
2
4
5
1
3
6
1.
Vessel power supply positive (+)
2.
Vessel power supply negative (-)
3.
In-line fuse (If your products power cable does
not have a built in fuse then an in-line fuse
should be fitted.)
4.
* Drain wire connected to vessel negative power
supply.
5.
Product power cable
6.
Vessel battery
Note:
* Only applicable to products that include a
drain wire on the product’s power cable.
Sharing a breaker
Where more than 1 piece of equipment shares a
breaker you must provide protection for the individual
circuits. E.g. by connecting an in-line fuse for each
power circuit.
D11637-2
2
4
4
1
3
+
-
1
Positive (+) bar
2
Negative (-) bar
3
Circuit breaker
4
Fuse
Where possible, connect individual items of
equipment to individual circuit breakers. Where this
is not possible, use individual in-line fuses to provide
the necessary protection.
Warning: Product grounding
Before applying power to this product,
ensure it has been correctly grounded, in
accordance with the instructions in this
guide.
CP100 / CP200