background image

 LifeTag Installation & Commissioning Guide

7

5. Take the Tag to every part of the vessel to which crew members have access, (i.e. every cabin, com-

partment and all extremes of the deck), to check if an alarm is initiated.
If any alarms occur, the system is NOT operating satisfactorily.

6. Take the appropriate action as detailed below, for either 

 System operating satisfactorily

 or 

 Sys-

tem not operating satisfactorily

, below.

System operating satisfactorily

If no alarms are initiated during the site survey, the LifeTag system is operating satisfactorily with the 
Base Station at its current location. Switch off the power, then permanently install the Base Station at 
that location, as detailed under 

 Fitting procedures

, below.

System not operating satisfactorily

If an alarm is initiated:
1. Hold down the Tag button for 5 seconds, to silence the alarm.
2. Release the Tag button, wait for 15 seconds then press it again for a further 5 seconds, to cancel 

the alarm.

If alarms occurred during the site survey, reposition the Base Station, then carry out another site 
survey. 

If alarms continue to occur, you need to install a system with Master and Repeater Base Stations (see 

 

Setting up a Master/Repeater Base Unit system

). For such a system, you need to set up a second Base 

Station as a Repeater. The original Base Station is the Master.

Setting up a Master/Repeater Base Unit system

Setting a Base Station as a Repeater

To set a Base Station to operate as a Repeater: 
1. Obtain a second LifeTag system. Temporarily place the Tags supplied with the second system, to 

one side

2. Place the Base Station from the second system and the original Base Station, so they are near to 

one another, with access to a common 12 V dc supply.

3. Remove the cover from the second Base Station as shown on 

page 3

, then locate the internal reset 

button and the LED indicator (see 

 Figure 11 

).

87064_3.book  Page 7  Friday, July 28, 2006  9:32 AM

Содержание Base Station

Страница 1: ...LifeTag System Installation Commissioning Guide Document reference 87064 3 Date July 2006...

Страница 2: ...Raymarine and SeaTalk are trademarks of Raymarine plc Handbook contents copyright Raymarine plc...

Страница 3: ...regulations when disposing of spent batteries Incorrectly fitting batteries or using the wrong battery types may result in unreliable or reduced system performance RF Energy TheLifeTagandLifeTagBaseSt...

Страница 4: ...ii LifeTag System Installation Commissioning Guide...

Страница 5: ...ion No 6 Self tapping screws x2 Base Station Straps x2 Strap extensions x2 Tags x2 Cable ties Buzzer bracket and fixing screws x2 CR2 3V lithium batteries x2 D8919 3 SeaTalk cable No 8 Self tapping sc...

Страница 6: ...ld be increased to 7 ft 2 m More than 7 ft 2 m from the path of a radar beam A radar beam can normally be assumed to spread 20 degrees above and below the radiating element Theproduct is supplied from...

Страница 7: ...rtheBaseStation If SeaTalk isavailable use this to connect the Base Station to SeaTalk as in Figure 6 If SeaTalk is not available use the SeaTalk cable to connect the Base Station to a 12 V dc power s...

Страница 8: ...r products connected via NMEA0183 Connecting Base Station when SeaTalk not available Figure 7 Base Station power connections when SeaTalk is not available Base Station D9242 3 Fuse required if the Sea...

Страница 9: ...nect switched 12 V output optional Theswitched 12 Voutputcan beused toautomaticallytriggerappropriateemergency systems when a MOB event occurs Figure 9 Optional 12 V output connection Base Station Ala...

Страница 10: ...survey To carry out a site survey 1 Referring to Figure 3 and Figure 4 place the Base Station at the location you intend installing it and temporarily connect it either to SeaTalk asdescribed in Figu...

Страница 11: ...to silence the alarm 2 Release the Tag button wait for 15 seconds then press it again for a further 5 seconds to cancel the alarm If alarms occurred during the site survey reposition the Base Station...

Страница 12: ...flashing If itis flashing you have successfully set the second Base Station as a Repeater with the original Base Station as the Master 7 Immediately switch off power to the Repeater Base Station Notes...

Страница 13: ...t Customer Support at www Raymarine com for advice and assistance If no alarms are initiated switch off the power then permanently install each Base Station at the locations used for the survey as det...

Страница 14: ...chargeable lithium CR2 3V batteries into each Tag as detailed in Figure 10 Base Station BeforeyoupermanentlyinstallaBase Station carryoutasitesurvey as detailed on Page6 to ensure you are fitting it t...

Страница 15: ...f you want to use the switched 12 V output from the Base Station connect as described in Figure 9 Figure 16 Summary of system connections D8982 3 1 3 5 4 Secure bracket to buzzer Drill two 1 8 inch 3...

Страница 16: ...dure When the LifeTag system has been installed and all Tags registered carry out the following commissioning procedure 1 SwitchonpowertotheBaseStationandcheck that the Alarm chirps as power is applie...

Страница 17: ...tcompletetheTag registration procedurewithin oneminuteof switching on power to the Base Station After the Base Station has been switched on for 1 minute the alarm chirps to indicate the end of the Tag...

Страница 18: ...te Before you can use a de registered Tag you must register it with the relevant BaseStation 3 Check that within the next 15 seconds registration starts This is indicated by alternate RED and GREEN LE...

Страница 19: ...l requirements and other relevant provisions of the R TTE Directive 1999 5 EC The original Declarations of Conformity may be viewed on the relevant product pages at www raymarine com Approvals Paramet...

Страница 20: ...td QuayPoint Northarbour Road Portsmouth HampshirePO6 3TD United Kingdom Tel 44 0 23 92693611 Fax 44 0 239269 4642 www raymarine com Raymarine Inc 21 Manchester Street Merrimack New Hampshire 03054 US...

Отзывы: