11
Changing from Programming mode to Operating Mode
Enter operating mode using the ‘Disable Remote Control
Set-up’ Button on the remote controller – or by using the
manual push buttons.
Changing from Operating Mode to Programming Mode
If no PIN present
- Re-cycle the power to your illuminator
- Use the Manual Buttons
If a PIN present
- Enter the PIN
- Full Re-set Procedure
(Power re-cycling only will not change the unit to
Programming Mode)
During Programming Mode and Operating Mode the two LED’s
indicate the following status
LHS SOLID GREEN:
Power Applied
LHS FLASHING GREEN: Remote controller IR receiver problem
(Max VRC distance is 8m (26ft) (both
modes)
RHS FLASHING AMBER: Indicates unit is in programming mode
(Programming Mode Only)
RHS SOLID AMBER:
Indicates that a valid command is being
received from the remote controller
(Programming Mode Only)
LHS FLASHING RED:
POE / Voltage supply problem detected
(both modes)
LHS SOLID RED:
Illuminator fault detected (both modes)
All functions of the remote controller and manual push buttons
are available in Programming Mode.
The only function of the Remote Controller available during Operating
Mode is LED Status Indicators Enable/Disable, entering a PIN or disabling
manual push buttons (if done at the same time as disabling the remote –
see P. 22)