Press the push-button. The word OFF appears on the display,
indicating the temperature curve is deactivated.
Repeat the following steps for each of the six points:
Press the push-button once again. A day number, preceded by
the letter "d", appears flashing on the display.
Turn the adjustment knob to adjust the day number to the desired
value.
Press the push-button once again. The current set point for this
day number appears flashing on the display.
Turn the adjustment knob to adjust the set point to the desired
value.
(1) All six points of the curve must be specified. If you do
not need six different points, repeat your last set point for each unnec-
essary point of the curve.
(2) To reduce the risk of errors:
it is not permitted to specify decreasing day numbers;
it is not permitted to specify increasing temperature set points;
the highest day number is 99;
the temperature variation can not exceed 3°F (1.6°C) per day.
When the six points of the temperature curve have been specified,
the temperature curve must be activated for the controller to begin to
automatically adjust the target room temperature.
Activate the temperature curve as follows:
Press the push-button once again.The word OFF appears
flashing on the display.
Turn the adjustment knob clockwise by one notch and leave it in
this position. The word ON appears flashing on the display and
after 10 seconds, the temperature curve pilot light turns on
indicating that the temperature curve is now activated.
NOTES: