2.5
Precautions for Use
1) Before connecting the laser to the DC power supply, make sure that it is connected to the
correct 24VDC voltage. Wrong connection to the power supply will cause irreversible damage
to the laser;
2) When the laser is running,
don’t
install or remove the output head;
3) Do not look directly at the output head, make sure to wear laser protective glasses when
operating the machine;
4) When not using the laser, please cover the protective cap and do not touch the output
terminal. When necessary, use special lens paper and alcohol to clean the lens;
5) The loss of optical power may be caused by incorrect operation in accordance with the above
specifications. Such loss will not be covered by the warranty;
6) Do not operate the laser in accordance with the control or adjustment methods specified in
this manual, which may cause damage.
2.6
Specifications
The specifications are listed in the following table.
Model
RFL-FDDL100X
RFL-FDDL80X
RFL-FDDL50X
Input power /W
>600
>500
>300
V DC
24VDC±10%
Continuous output
power rate/W
>100
>80
>50
Power instability
≤1%
Wavelength range
/nm
915±10nm
,
Other wavelengths can be customized
Indicating laser
650±10nm
,
0.25
~
1mW