background image

Wuxi Raycus Fiber Laser Technologies Co., Ltd.

User Guide of Raycus 500W

2000W laser

33

to occur, please contact Raycus.

T1/T2/T3/T4 Alarm

Instruction:

Low temperature/high temperature alarm of the laser. The sensor in the laser

detects an abnormal temperature inside the laser. A high-temperature /

low-temperature error occurs when the temperature at the monitoring point

exceeds the set upper / lower limit.

Solution:

High temperature alarm, please check if the water-cooling system is normally

working, the water temperature is set correctly, and the water connection is

correct. When the water cooling system works normally and the water

temperature drops below 30°C, restart the laser. If the alarm continues, please

contact Raycus.

Low temperature alarm, please check if the actual water temperature of the water

is too low. In addition, a low ambient temperature may also cause a low

temperature alarm when the laser is cold. Please wait until the water temperature

of the water rises above 10°C. If the alarm continues, please contact Raycus.

Hum Alarm

Instruction:

The laser detects that the current water-cooled plate temperature is lower than

the internal dew point temperature, There is a risk of condensation in the

equipment internal.

Solution:

Stop using the laserimmediately, Waiting for ambient temperature to come back

to normal, Repower the laser. If the alarm continues to occur, please contact

Raycus.

In addition to the above, if there are any questions or errors in using of thelaser, you can

contact Raycus to get help.

6 Warranty, Return and Maintenance

6.1 General Warranty

Raycus warrants that all Raycus fiber laser products are conformed to applicable

productspecifications under normal use and are free from defects in materials and workmanship.
Thewarranties start on the date of shipment from Raycus for a period of time as set forth in
theapplicable purchase contracts or product specifications.

Raycus has the right to choose to repairor replace any product that proves to be defective in

materials and workmanship selectivelyduring the warranty period. Only products with particular
defects are under warranty. Raycusreserves the right to issue a credit note for any defective
products produced in normal conditions.

6.2 LimitationsofWarranty

The warranty does not cover the maintenance or reimbursement of our product of which

theproblem results from tampering, disassembling, misuse, accident, modification,
unsuitablephysical or operating environment, improper maintenance, damages caused by those

 

 

 

 

 

 

 

武汉锐科

 

 

Содержание RFL-A500D

Страница 1: ...A0 S RFL A500D 2000D RFL A500D 2000D JS02 20201222 20210105 20210106 20210118 20210120...

Страница 2: ...Fiber Delivered Direct Diode Lasers User Guide RFL A500D 2000D...

Страница 3: ...es 5 2 Product Description 6 2 1 Features 6 2 2 Model Configuration 6 2 3 Package Contents 7 2 4 Unpacking and Inspection 7 2 5 Operation Environment 8 2 6 Specifications 9 2 7 Properties of Products...

Страница 4: ...ng Process 24 4 6 Selection of Control Mode 24 4 7 Pilot Light to Control 32 4 8 Steps of Shutting Down 32 5 Alarms and Solutions 32 5 1 Alarms Display 32 5 2 Alarm Solutions 33 6 Warranty Return and...

Страница 5: ...247 1 clause 9 this type of laser is a class 4 laser instrument The product emits laser radiation with a wavelength of 915nm or around 915nm and the optical power radiated by the output head is greate...

Страница 6: ...safety labels and its location These safety signs include safety warnings laser output head warnings product nameplates etc The safety identification details are as follows Table1 Safety Identificatio...

Страница 7: ...Any interruption from the protective earth will electrify the enclosure which may result in personal injury b Make sure that the correct voltage of the AC power source is used Failure to connect the...

Страница 8: ...ion lower power consumption The fiber laseris compact and ready to use Because of its flexible form it can be easily integrated with the system equipment Main Features a Flexible output optical cable...

Страница 9: ...ble A indicates QBH interface B indicates SMA905 interface C indicates D80 interface 7 Cooling method W indicates water cooling T indicates TEC air cooling A indicates air cooling 2 3 Package Contents...

Страница 10: ...is precise opticinstrument any vibration or impact to the output head and twist orexcessive bend to the cable will damage the instrument 2 5 Operation Environment The basic operation conditions are l...

Страница 11: ...ent the water temperature of the laser can only be set in the blue region of the dew point comparison table so this method has certain limitations b By changing the temperature and humidity of the wor...

Страница 12: ...instructions may result in the loss of laser power and such loss will not be covered by the warranty 2 7 Properties of Products Table 5Properties of Products Model RFL A500D RFL A1000D RFL A1500D RFL...

Страница 13: ...60Hz three phase 380VAC 10 50 60Hz TN C Control Mode RS 232 AD Other Parameters Dimensions W H D mm 485 237 679 485 237 765 Weight kg 50 Operating Ambient Temperature 10 40 Humidity 70 Storage Temper...

Страница 14: ...chnologies Co Ltd User Guide of Raycus 500W 2000W laser 12 Figure 3a Top View of 500W 1000W Laser unit mm Figure 3b Top View of 1500WLaser and 2000WLaser unit mm 3 2 Output Head and Installation Figur...

Страница 15: ...ibited to disassemble the output head by personnel notapproved by Raycus or the warranty is void 3 3 Cooling Requirements Table6 Cooling Requirements Parameters unit RFL A500D RFL A1000D RFL A1500D RF...

Страница 16: ...t time check the entire water system and the joint for water leakage The external water pipe must be installed and connected according tothe inlet IN and outlet OUT by the laser Otherwise the laser ma...

Страница 17: ...cable from treading pinching or excessive bending duringinstallation g In the installation of laser output cable and output head process please make sure that the surrounding environment is clean oth...

Страница 18: ...ser The system will enter control mode according topreviously programme and subsequent operations in CTRL INTERFACE 2 POWER Power Indicator indicates that the power is switched on when the green LED i...

Страница 19: ...ode Input analog voltage signal trouble signaloutlet RS 232 RS 232 serial port Provide remote control and alarm information storage for the laser SERVICE The laser switch and security interlocking int...

Страница 20: ...ty Interface Each pin is defined as shown in table 7 below Table 7 SERVICE definition PIN Name Function Remark 1 PowerA Remote switch Passive contact Can t be connected to external voltage or ground S...

Страница 21: ...e 9 MOD Cable The Cable for Modulation Signal The modulation signal cable core is positive 24V and the external metal mesh is negative GND Before the modulated signal is connected to the laser please...

Страница 22: ...The Modulation Signal 4 4 3 Control Interface The pin number of CTRL INTERFACE is shown in figure 13 Figure 11DB25 Control Interface The definitions of the control interface are as follows Table 9 Co...

Страница 23: ...Signal 0V 10V 10mA 23 Laser Power Output Power indication 0V 3 8V 10mA 24 Alarm Output Fault Signal Fault 24V 100mA normal 0V 25 AGND GND of PIN22 PIN23 0V other NC None Please check the control volta...

Страница 24: ...3 PIN8 and PIN24 internal circuit 4 4 4 RS 232 Serial Port Figure 14 shows the pin number of RS 232 serial port Figure 14Pin Number of RS 232 Serial Port And the definitions of the pins are in the fol...

Страница 25: ...s to set up parameters MOD Analog Quantity and control laser enable signal externally Internal control mode is to set up parameters and control laser enable signal internally Each control modes can be...

Страница 26: ...larm Laser alarm Control Interface Laser EN Control Interface s the pin LASER ON is high level Interlock Control Interface s the InterLock is on Emission ON The laser is emitting laser REM The laser i...

Страница 27: ...er Control Set parameters Laser Power Frequency Duty Ratio Set After Setting parameter Need to click set Emission on Pressing the button the laser is emitting laser button is unavailable the laser is...

Страница 28: ...ncy duty ratio and the percentage of power by upper computer software d The external MOD interface provides modulating signal for the lase e Enable the laser to emit laser light through one of the fol...

Страница 29: ...Wuxi Raycus Fiber Laser Technologies Co Ltd User Guide of Raycus 500W 2000W laser 27 Figure 18Control Sequence Diagram of PLUSE Pattern in External Control RS232 Mode...

Страница 30: ...ion Procedure of External AD mode a When PIN 7 and PIN 9 of the DB25 control interface is applied to 24V the laser enters the externalAD mode b Turn key switch anti clockwise to REM position or turn k...

Страница 31: ...ernal MOD interface provides modulating signal for the laser f Enable the laser to emit laser light through one of the following ways 1 PIN 6 and PIN 9 of the DB25 control interface is applied to 24V...

Страница 32: ...ntil the internal main control board circuit initialization is completed c Setting the power of the laser by upper computer software thenclick SET to send a command of emitting laser d Press Laser but...

Страница 33: ...ser beam cannot exist simultaneously If there is no pilot light please check if the laser enable signal is off 4 9 Steps of Shutting Down Please turn off the laser in the order below a Release the but...

Страница 34: ...s Laser On Button Alarm Instruction This alarm occurs The LASER button on the front panel has been pressed before the laser is powered on Solution Please power off and release the LASER button Repower...

Страница 35: ...point temperature There is a risk of condensation in the equipment internal Solution Stop using the laserimmediately Waiting for ambient temperature to come back to normal Repower the laser If the al...

Страница 36: ...operation failure to do so may void this warranty Accessories and fiberconnectors are not covered by this warranty 6 3 Service and Repair a Do not open the device There are no user serviceable parts e...

Отзывы: