Before leaving the site, check that the operation of cooker
timer and thermostat are capable of controlling the burner
correctly. Check the operation of burner control box.
In the event of a flame failure the control box should cut
off the oil supply by closing the solenoid valve. The reset
buttons will then be illuminated.
WAIT 1 MINUTE BEFORE RESETTING THE CONTROL
BOX.
1. Advise the User that, for continued efficient and safe
operation of the appliance, it is important that adequate
servicing is carried out at regular 12 monthly intervals.
2. Hand the Operating Instructions to the User and
demonstrate the correct operation of the appliance and
system controls.
3. Leave the Installation and Servicing Instructions with
the User.
23
Commissioning Instructions
ANCILLARY CONTROLS CHECK
INSTRUCT THE USER