The Rayburn Cookmaster Plus 208K is a cooker
providing domestic hot water and cooking facilities. It is
available with a vertical flue outlet only, with the oil
burner operating on natural draught.
The boiler is designed for use in an open vented water
system only, with gravity D.H.W. primaries.
Alternatively, the Rayburn Cookmaster 200K is a non-
boiler model. However, with this model the idling
temperature may be higher.
These appliances must only be used with Commercial
Grade C2 Kerosene.
IMPORTANT:
IN ORDER TO ACHIEVE THE OPTIMUM
PERFORMANCE FROM THIS APPLIANCE, IT IS
ESSENTIAL THAT THE INITIAL COMMISSIONING OF
THE APPLIANCE IS UNDERTAKEN BY SELECTED
TRAINED INSTALLING SERVICE ENGINEERS.
YOUR RAYBURN STOCKIST WILL PROVIDE ADVICE
ON THE LOCATION OF THE NEAREST INSTALLING
ENGINEER. WE ALSO RECOMMEND YOU CONTRACT
OUT THE PERIODIC SERVICING OF THE
APPLIANCE TO THIS INSTALLING/SERVICING
ENGINEER.
REMEMBER, when replacing parts on this appliance,
use only spare parts that you can be assured conform
to the safety and performance specification that we
require. Do not use reconditioned or copy parts that
have not been clearly authorised by AGA.
This appliance must be commissioned by a competent
engineer, such as OFTEC approved.
THIS APPLIANCE IS A CONTROLLED SERVICE BY
DEFINITION AND REQUIRES EITHER FITMENT
UNDER THE REMIT OF BUILDING CONTROL OR
INSTALLATION BY AN OFTEC REGISTERED 105
TECHNICIAN (CLASSED AS A COMPETENT
PERSON) WHO CAN SELF CERTIFY HIS OWN
WORKS.
The installation of the appliance must be in accordance
with the relevant requirements of the current Building
Regulations, current I.E.E. Wiring Regulations and the
byelaws of the local Water Undertaking.
Installation and Servicing
Instructions for Rayburn
Cookmaster 200K and Rayburn
Cookmaster Plus 208K Oil-Fired
Cooker
INTRODUCTION
INSTALLATION INSTRUCTIONS
1
02/06 EINS 511029
Consumer Protection Act 1987
As responsible manufacturers we take care to make sure that our
products are designed and constructed to meet the required safety
standards when properly installed and used.
IMPORTANT NOTICE: PLEASE READ THE ACCOMPANYING
WARRANTY.
Any alteration that is not approved by Aga, could invalidate
the approval of the appliance, operation of the warranty and could also
affect your statutory rights.
Control of Substances - Health and Safety
Important
This appliance may contain some of the materials that are
indicated. It is the Users/Installers responsibility to ensure that the
necessary personal protective clothing is worn when handling,
where applicable, the pertinent parts that contain any of the listed
materials that could be interpreted as being injurious to health and
safety, see below for information.
Firebricks, Fuel beds, Artificial Fuels
- when handling use
disposable gloves.
Fire Cement
- when handling use disposable gloves.
Glues and Sealants
- exercise caution - if these are still in liquid
form use face mask and disposable gloves.
Glass Yarn, Mineral Wool, Insulation Pads, Ceramic Fibre,
Kerosene/Gas Oil
- may be harmful if inhaled, may be irritating to
skin, eyes, nose and throat. When handling avoid inhaling and
contact with skin or eyes. Use disposable gloves, face-masks and
eye protection. After handling wash hands and other exposed
parts. When disposing of the product, reduce dust with water
spray, ensure that parts are securely wrapped.
Boiler Model
Non-Boiler
Model
Cooker
Cooker
Cooker
Cooker
LOW
HIGH
LOW
HIGH
Heat Input
kW
2.43
7.42
2.16
5.48
Btu/h
8,312
25,321
7,386
18,700
Heat Output
kW
0.73
2.34
Water
Btu/h
3,000
8,000
Oil Input
cc/minute
4.0
13.0
3.5
8.5
Rate
Boiler Water Connections
Weight of
305Kg
Flow (one)
Rp 1 (1in BSP Int)
Appliance
Return (one)
Rp1 (1in BSP Int)
Appliance Overall
Height: 995mm
Both connections are located towards the
Dimensions
Width: 940mm
rear edge of the appliance L.H. side panel.
Depth: 575mm
Oil Valve Inlet
Rp
1
¼
4
(
1
¼
4
in BSP Int)
FUEL
- COMMERCIAL GRADE C2 KEROSENE
Better than you ever imagined