Fast and Furious Arcade
41 |
P a g e
Problem
Possible Cause
Solution
Coin meter does not click
during test.
No pulse to meter.
Check wiring from meter to PCB board.
Faulty meter.
Replace coin meter.
Blown fuse(s) on PCB
Replace 12vdc 5A fuse(s) on PCB.
Exits Test Mode every 3
seconds.
Test button stuck in ON
position.
Slide or toggle button off after Test Menu appears
Improper number of credits
given when bills are
inserted.
Incorrect setting in
Pricing Adjustments.
Adjust pricing settings.
Faulty wiring.
Disconnect cabinet from AC power. Verify wires
are firmly connected to bill validator and ground
wires are properly connected. Verify no wires are
frayed or shorting to ground.
Compressor does not turn
on/low humming noise
coming from the
compressor
Compressor power cut
off while it was
running.
Shut off cabinet via both switches at rear of
cabinet. Leave off for 3 minutes, then power back
on.
Onscreen message:
“Version Mismatch”
appears after
reinstalling/updating
software
One or more cabinets is
running a different
version of software.
Enter test menu on each cabinet. Check the
version number in the top left corner. Using the
USB drive that came with your game (or a USB
drive from your distributor) install latest version
to any mismatched cabinets (
see pg. 37 for
installation procedure
). Once installation is
complete, power cycle all cabinets. The message
should disappear.
Software install/update
did not complete
correctly.
Top and bottom monitor
images are reversed
Connections at PC are
connected to the
incorrect ports.
Verify that top monitor HDMI cable is connected
to the HDMI port on the video card at rear of PC.
Verify that bottom monitor HMDI-DVI cable is
connected to the DVI port on video card at rear of
PC. If not, swap the cables around and reboot the
cabinet.