Fig.53
Fig.51
8.22 TO REMOVE PANEL CONTROL BOX
(Fig. 50,51).
Remove the front panel (fig. 39).
Pull the control panel box until it is
slightly out of the boiler.
As doing so move the box forward
until the control box becomes free.
This will allow free access to lower
part of the boiler.
Fig.52
51
Fig.50
8.23 TO REMOVE/REPLACE CONTROL
BOARD (Fig.52).
Remove the front panel (fig. 39).
Remove the the panel control box (sect.
8.22).
Detach all connectors from control board,
unscrew the four screws and lift up.
Replace in reverse order.
8.24 TO REMOVE/REPLACE DIGITAL
DISPLAY BOARD.
Remove the front panel (fig. 39).
Remove the panel control box (sect.
8.22), and let it fix at the depression
chamber like in fig. 52.
Unscrews the four screws that fix the
cover panel control box and lift up.
Detach all connectors from control board,
unscrew the four screws and lift up.
This will allow free access to digital
display. Detach the connector and
unscrew the four screws and lift up.
Replace in reverse order.
8.25 EXTERNAL CONTROL CONNECTION
(Fig. 53)
Remove the front panel (fig. 39).
Remove the external wire link on the
panel control box.
Replace with external wire controls.
(These must be volt free).
Содержание HE 25 S COMPACT
Страница 2: ...2...
Страница 4: ...4...
Страница 5: ...5...
Страница 25: ...5 5 FLUE TERMINAL POSITION 25...
Страница 54: ...10 ELECTRICAL SYSTEM DIAGRAM 54 Fig 55...
Страница 55: ...55 11 SPARE PARTS Fig 56...
Страница 61: ...61...
Страница 62: ...62...
Страница 63: ...63 www centralheating co uk Benchmark Commissioning and Servicing Section...
Страница 64: ...64 FLOWCHART FOR CO LEVEL AND COMBUSTION RATIO CHECK ON COMMISSIONING A CONDENSING BOILER...
Страница 65: ...65 12 1 ANALYSER CHECK LIST...
Страница 66: ......