![Ravenheat HE 25 S COMPACT Скачать руководство пользователя страница 43](http://html1.mh-extra.com/html/ravenheat/he-25-s-compact/he-25-s-compact_instructions-for-use-installation-and-servicing_3859839043.webp)
system, and to the building, in the event
of the system remaining inoperative during
frost conditions.
- Explain the function and the use of the
boiler, the summer/winter button, the
ON/OFF switch and the reset of the digital
display.
- Explain and demonstrate the function of the
temperature controls, radiator valves etc. for
the economic use of the system.
- If an external time clock is fitted, then draw
attention to ensure the boiler timer is left in
the manual position.
- Stress the importance of regular servicing
by a qualified Heating Engineer and that a
comprehensive service should be carried
out AT LEAST ONCE A YEAR.
- Fill in the Benchmark log book and leave
completed with the customer.
- Explain to the user how to isolate the
appliance from the gas, water and
electricity supplies and the locations of
all drain points.
RATIO BETWEEN FAN SPEED
AND HEAT INPUT
Fig. 38
TABLE 10/A
TABLE 10/B
6.15 RANGE RATING CENTRAL HEATING
OR/AND DOMESTIC HOT WATER
The boiler comes set, in Central heating,
at the MID RANGE of its output.
The boiler has already been adjusted by the
manufacturer during production. If the
adjustments need to be made again, observe
the following procedures.
The adjustment to fan speed must be
strictly in the sequence indicated, by
qualified personnel only.
To check max fan speed, see tables 10/A
and 10/B.
Press INFO and arrow down buttons together
(item 6 and 4 fig. 1) for 5 seconds to enter in
USER PARAMETERS mode.
- Use arrow up and arrow down buttons
(item 3 and 4 fig. 1) to select the
followings options:
- P001 CH max fan speed.
- P002 DHW max fan speed.
- Press enter (item 1 fig. 1) to
select CH or DHW fan speed.
Adjust if necessary.
6.16 TEST MODE
It is possible to activate the test mode by
USER PARAMETERS (see section 1.4) or
directly by pressing the INFO and the
RESET buttons together (item 6 and 2 fi g. 1)
for 5 seconds.
Press the arrow up and the arrow down
buttons to set the maximum or minimum fan
speed.
The function is enabled for maximum 15
minutes.
Press RESET to esc test mode.
6.17 INSTRUCTING THE USER
After completion of the installation and
commissioning of the system, the installer
should hand over to the householder by
taking the following actions:
- To the Householder explain his/her
responsibilities under The Gas Safety
(Installation and Use) Regulations
1998.
- Explain and demonstrate the lighting
and shutting down procedures.
- Show the user the location of the filling
valve and how to top-up the system
pressure correctly.
- Explain the operation of the boiler
including the use and adjustment of
ALL system controls which should be
fully explained to the householder. This
will ensure the optimum fuel economy
for the household requirements of both
heating and hot water consumption.
Advise the User of the precautions
necessary to prevent damage to the
43
Содержание HE 25 S COMPACT
Страница 2: ...2...
Страница 4: ...4...
Страница 5: ...5...
Страница 25: ...5 5 FLUE TERMINAL POSITION 25...
Страница 54: ...10 ELECTRICAL SYSTEM DIAGRAM 54 Fig 55...
Страница 55: ...55 11 SPARE PARTS Fig 56...
Страница 61: ...61...
Страница 62: ...62...
Страница 63: ...63 www centralheating co uk Benchmark Commissioning and Servicing Section...
Страница 64: ...64 FLOWCHART FOR CO LEVEL AND COMBUSTION RATIO CHECK ON COMMISSIONING A CONDENSING BOILER...