background image

5

14.Use the supplied wire cutter to strip back the insulation on the lead wire and 

connect the supplied male 1/4” quick disconnect terminal (P/N 405-2001-016).

15.Route the grey wire in the front panel to the red wire underneath the instrument 

panel and connect the quick disconnect terminals.

16.Carefully replace the console front panel.

Note:  

Do not replace the pump instrument panel until the “Viper Pro Firmware 
Update” section on page 6 is 
completed.

Re-pin the Viper Pro Harness

The Viper Pro interface cable must be modified to take advantage of the 
automatic power down feature on the field computer. Review the following 
procedure to complete the installation of the field update kit.

1. Locate the round, 16-pin cable connector (female pins) disconnected from the 

back of the Viper Pro.

2. Remove the two screws on the connector retainer and carefully unscrew the 

shroud from the connector.

It may be necessary to use a set of pliers to help unscrew the connector. Be 
careful not to damage the plastic connector or shroud.

3. While looking at the face of the connector, locate pin locations 2 and 14.

4. Insert the supplied Amp pin extractor tool (P/N 321-000-392) into the pin 2 

location and depress the plunger to remove the pin.

16 Pin Interface 

Connector

Содержание Viper Pro

Страница 1: ...for Raven Viper Pro Field Update Guide...

Страница 2: ...dustries for update Contact a local Raven dealer for assistance Important Safety Information Read the following procedures carefully before installing the field update kit and follow all safety inform...

Страница 3: ...Pro to prevent damage to the field computer 3 Locate the instrument panel with the product pump and hydraulic shut off switch in the vehicle cabin Remove the 4 screws and carefully lift the instrument...

Страница 4: ...ring the field computer approximately 2 in 5 cm from the factory splice Note A crimp connector will be installed on the red power wire still connected to the factory splice later in this process 7 Loc...

Страница 5: ...st located in the right rear corner below the cabin 11 Open the panel on the front side of the console along the right side of the vehicle cabin 12 Locate the grey wire with the female 1 4 quick disco...

Страница 6: ...ed to take advantage of the automatic power down feature on the field computer Review the following procedure to complete the installation of the field update kit 1 Locate the round 16 pin cable conne...

Страница 7: ...onnector labeled CAN under the pump switch instrument panel The connector should be located near the factory power and ground cluster found earlier in the field update process 2 Disconnect the 4 pin c...

Страница 8: ...e disk contents 9 Double click on the ViperST10 Programmer exe icon to begin the update process The update may take approximately 15 seconds to begin When the update is in progress the Viper Pro will...

Страница 9: ...version 22 is shown If so the firmware update has been successful 16 Check the software version displayed on the screen a If the software version is 3 5 0 21 or newer no software update is necessary t...

Страница 10: ...web site 1 Insert the provided USB flash drive P N 063 0173 427 into the Viper Pro 2 Press the power button on the Viper Pro field computer 3 Touch the Display Program List button when the following...

Страница 11: ......

Страница 12: ...x Falls SD 57117 5107 Fax 605 331 0426 www ravenprecision com www ravenhelp com Notice This document and the information provided are the property of Raven Industries Inc and may only be used as autho...

Отзывы: