CABLES AND WIRING

Wiring power to the Envizio Pro or Viper Pro field computer, Switch Pro switch box, and the CAN nodes is 

especially important for proper operation of the system. Many issues can be corrected by diagnosing and fixing 

problems related to improper wiring of the power and ground.

BEST WIRING PRACTICES

• Console power should be wired to a controlled clean power source.
• All ground wires must be connected directly to the battery ground. DO NOT use a chassis ground.

High current power is supplied to the Switch Pro through the existing SCS console cable.
• Make sure the red power lead is connected to the machine’s positive battery terminal.
• Make sure the white ground lead is connected to the machine’s negative battery terminal.

NOTE:

If an existing Raven SCS 440, 450, 4400 system has not previously been installed prior to purchase of 

the Switch Pro system, additional cabling and hardware will be required when installing the Switch Pro 

system. Please contact a local dealer for specific flow control components required and installation 

assistance.

CONNECTING THE SWITCH PRO

NOTE:

For kits including a combo cable (P/N 115-0171-820 or 821), refer to Appendix A, Switch Pro Combo 

Cable, for installation instructions.

Refer to Appendix B, System Diagrams, for detailed system connection diagrams. These drawings may be helpful 

for understanding the Switch Pro system and connections.
1. Refer to the Envizio Pro or Viper Pro Installation & Operation Manual when installing the Envizio Pro or Viper 

Pro interface cables (P/N 115-0171-745 or 746). These cables are included in the core Envizio Pro or Viper Pro 

systems and detailed installation procedures are detailed in the installation section for the Envizio Pro or Viper 

Pro field computer.

2. Once the Envizio Pro/Viper Pro interface cables are installed, connect the auxiliary power output connector to 

the back of the Switch Pro.

3. Connect the Switch Pro to the existing SCS console cable.

a. For Switch Pro systems replacing SCS 4400 consoles, connect the existing console cable directly to the 

cable port on the back of the Switch Pro switch box.

b. Switch Pro systems replacing SCS 440/450 consoles require the Switch Pro console cable (P/N 115-0171-

803) to connect with the existing SCS 440/450 console cable. Connect the large round connector to the 

back of the Switch Pro. The existing SCS 440/450 console cable will connect to the smaller male connector 

on the Switch Pro console cable (P/N 115-0171-803).

Switch Pro Cable Port

Logic Power Port

Содержание Switch Pro

Страница 1: ...Raven Switch Pro Installation Reference Manual Manual No 016 0171 219 Rev E 07 17 E29805 Copyright 2017...

Страница 2: ...sible for any modifications or repairs made outside our facilities nor damages resulting from inadequate maintenance of this system As with all wireless and satellite signals several factors may affec...

Страница 3: ...ing Switch Pro 3 Logic Power LED 3 Increase Decrease Flow Switch 3 Master Switch 4 3 Way Selectable Section Switches 4 Using AccuBoom Override 4 Appendix A Switch Pro Combo Cable 5 Combo Cable Install...

Страница 4: ...Table of Contents ii Raven Switch Pro Installation Reference Manual Coverage Map Issues 19 CAN Troubleshooting 19...

Страница 5: ...er to the Best Wiring Practices section on page 4 section later in this chapter for more information If an existing Raven SCS 440 450 4400 system has not previously been installed prior to purchase of...

Страница 6: ...ing hazards If the Switch Pro will be mounted together with an Envizio Pro or Viper Pro field computer Securely fasten the RAM mounting arm Envizio Pro to a suitable flat surface Once mounted the RAM...

Страница 7: ...nt the Switch Pro either above or below the field computer Optional RAM Mount components are also available for remote mounting of the Switch Pro unit See the Switch Pro Kit Contents section on page 6...

Страница 8: ...cable P N 115 0171 820 or 821 refer to Appendix A Switch Pro Combo Cable for installation instructions Refer to Appendix B System Diagrams for detailed system connection diagrams These drawings may b...

Страница 9: ...ibration values programmed into the console These values are stored on the SCS console and must be programmed into the new console with the Switch Pro system See the Preparation section on page 1 for...

Страница 10: ...1 1 1 1 Envizio Pro Console 063 0172 865 1 1 1 1 E Pro Switch Pro Mounting Bracket 107 0171 841 1 1 1 1 1 1 Power Ext Cable 115 0171 810 1 1 Switch Pro Console Cable 115 0171 803 1 Switch Pro Combo C...

Страница 11: ...higher Refer to the field computer Installation Operation Manual for more information on software updates USING SWITCH PRO LOGIC POWER LED The logic power LED displays the status of logic power This...

Страница 12: ...AccuBoom and coverage maps Refer to the Envizio Pro or Viper Pro Installation Operation Manual for more information on setting up and using AccuBoom features OFF Manually control the section Off This...

Страница 13: ...make sure the cable is configured for the speed source being used with the Switch Pro system When using the Envizio Pro internal DGPS Receiver as the speed source make sure the T2 and T1 terminals ar...

Страница 14: ...to SCS 440 450 cabling connect the 16 pin connectors on the existing console cable and combo cable If the speed and pressure sensors will be used reconnect the existing sensor cables to the Speed 14 p...

Страница 15: ...o troubleshoot the Switch Pro system Be sure to locate the appropriate system diagram for the Switch Pro system currently installed SWITCH PRO FOR SCS 440 450 CABLED SYSTEMS The following diagrams ill...

Страница 16: ...APPENDIX B 12 Raven Switch Pro Installation Reference Manual FIGURE 1 Envizio Pro with Switch Pro for SCS 440 450 Cabled Systems...

Страница 17: ...13 FIGURE 2 Viper Pro with Switch Pro for SCS 440 450 Cabled Systems...

Страница 18: ...Reference Manual SWITCH PRO FOR SCS 4400 CABLED SYSTEMS Refer to the following diagrams in reference to Switch Pro systems replacing an SCS 4400 console with the 117 0171 168 kits FIGURE 3 Envizio Pro...

Страница 19: ...15 FIGURE 4 Viper Pro with Switch Pro for SCS 4400 Cabled Systems...

Страница 20: ...anual SWITCH PRO COMBO CABLE TO SCS 440 450 SYSTEMS Refer to the following diagram when using the combo cable P N 115 0171 820 for SCS 440 450 Systems Kits 117 0171 169 or 170 FIGURE 5 Envizio Pro wit...

Страница 21: ...17 FIGURE 6 Viper Pro with Switch Pro Combo Cable for SCS 440 450 Cabled Systems...

Страница 22: ...ce Manual SWITCH PRO COMBO CABLE TO SCS 4400 SYSTEMS Refer to the following diagram when using the combo cable P N 115 0171 821 for SCS 4400 Systems Kits 117 0171 171 or 172 FIGURE 7 Envizio Pro with...

Страница 23: ...19 FIGURE 8 Viper Pro with Switch Pro Combo Cable for SCS 4400 Cabled Systems...

Страница 24: ...APPENDIX B 20 Raven Switch Pro Installation Reference Manual...

Страница 25: ...ling if applicable Check CAN terminators Check for 12 volts on Switch Pro power connector Verify Envizio Viper Pro product control Configuration Product control must be set to CAN Boom valves do not t...

Страница 26: ...up properly Check the boom setup on the console Nodes not completely programmed Check node calibration and ensure all calibration values are entered and correct The boom is disconnected Check the conn...

Страница 27: ...no rate applied Cannot achieve target rate Driving too fast for vehicle Speed may exceed capabilities of vehicle to deliver product Slow the vehicle down during application or configure product contr...

Страница 28: ...APPENDIX C 24 Raven Switch Pro Installation Reference Manual...

Страница 29: ...i Combo Cable 5 Speed Input Terminal Configuration 5 Mounting Bracket iv Mounting Tips iv Preparation iii K Kit Contents 2 L Logic Power LED 3 M Master Switch 4 O Overview System 1 R Required Calibrat...

Страница 30: ...Index 22 Raven Switch Pro Installation Reference Manual...

Страница 31: ...r s responsibility The Return Materials Authorization RMA number must appear on the box and all documentation including proof of purchase must be included inside the box to be sent to Raven Industries...

Страница 32: ...claim and send it to Raven Industries for final approval The freight cost to Raven Industries will be the customer s responsibility The Return Materials Authorization RMA number must appear on the box...

Отзывы: