Chapter 5
38
SCS 660 & 660M Serial Interface for Granular Applications Installation & Service Manual
Control Valve Delay and Valve Advance
Note:
PGM 126 requires Rev D or greater to support the Valve Advance feature.
The Control Valve Delay feature allows the user to set a delay between the time the booms are turned on and
when the console begins to control the flow rate. The delay is active if the time between turning off the booms
and turning them back on is less than 30 seconds.
The Valve Advance feature allows the user to set the amount of time (in seconds) between the time the boom
sections are turned off and the valve is opened and in automatic control.
Press the SPEED CAL button until the console displays the message “CONTROL VALVE DELAY” and four
digits (
X
X
X
X ). The
first
digit is the Control Valve Delay value. The value (1 - 9) represents the number of
seconds of delay in turning on automatic control. A value of 0 means that there is no delay. The
third
digit is
the Valve Advance value. The value (1 - 9) represents the number of seconds of delay in which the valve will
be opened upon all boom sections being turned OFF in automatic control. A value of 0 means that there is no
advance.
Note:
A beginning value of 1020 is recommended for low rate situations to build up pressure when
turning the master switch on. For best results, approach the headlands at consistent speeds while
turning all boom sections off.
Zero Speed Shut-Off
The Zero Speed Shut-Off function is active when C-FC (fast-close valve) or C-PC (PWM close valve) is
selected, and cannot be disabled. The valve will receive a decrease signal and run closed when the speed
drops to 0.7 mph or less. The only way the console can operate under this speed is in the manual mode.
When the Zero Speed Shut-Off has occurred, the master switch must be turned off and back on to restart the
system. If a constant speed greater than 0.7 mph is not reached within 10 seconds, the Zero Speed Shut-Off
will occur again.
Data Lock Feature
The Data Lock feature prohibits data entry without the data-lock code. The four-digit code must be entered
within 15 seconds.
Activate the Data Lock Code
1.
Press the DATA MENU button until the message “PRESS ENTER FOR DATA-LOCK” appears on the
console’s display.
2.
Press ENTER. The message “NEW CODE E” will appear in the display.
3.
Enter the 4-digit data lock code of your choice within 15 seconds.
4.
Press ENTER.
Change the Data Lock Code
1.
Press the DATA MENU button until the message “PRESS ENTER FOR DATA-LOCK” appears on the
console’s display.
2.
Press ENTER. The message “OLD CODE E” will appear in the display.
3.
Enter the old 4-digit data lock code within 15 seconds.
4.
Press ENTER. The message “NEW CODE E” will appear in the display.
Содержание SCS660M
Страница 1: ...SCS 660 660M Serial Interface for Granular Applications Installation Service Manual...
Страница 18: ...Chapter 3 12 SCS 660 660M Serial Interface for Granular Applications Installation Service Manual...
Страница 29: ...4 Manual No 016 0159 845 23 Installation FIGURE 15 SCS 660M Console Cabling Diagram...
Страница 54: ...Chapter 7 48 SCS 660 660M Serial Interface for Granular Applications Installation Service Manual...
Страница 56: ...Chapter 8 50 SCS 660 660M Serial Interface for Granular Applications Installation Service Manual...
Страница 58: ...Index 52 SCS 660 660M Serial Interface for Granular Applications Installation Service Manual...