Manual No. 016-0159-845

35

Console Programming and Calibration

Data Logger On/Off

The data logger uses communication strings to pass data through the serial port based on the values entered 
in DATA LOGGER TRIGGER VALUE and DATA LOGGER TRIGGER UNITS. Whenever a value or console 
switch is changed, data strings are sent by the console to the remote computer. 

Note:

When connecting to a Raven field computer, it is not necessary to turn the DATA LOGGER on.

Some options within the Data Menu are unavailable when certain other features are active. The console data 
printout is not available when the data logger is on. 

Remote Computer to SCS 660 Console Data Strings

All request strings begin with $R, indicating a Raven communication string.

PRESS ENTER TO 

CAL PRESSURE

Used to set the zero point of the pressure transducer for pressure display.

OFF RATE PERCENT 

30

Used to set the percent of off-target value. The alarm sounds when the actual rate is off 
from the target rate by a specified percentage. The off-target value is preset to 30%, but 
may be changed to a different number.

HIGH PWM OFFSET 

253

Used to set the maximum desired RPM or hydraulic output of the Pulse-Width 
Modulated (PWM) control valve.

1.

In the DATA MENU, use the arrow keys to advance to HIGH PWM OFFSET 
253.

2.

Move the product switch to MAN and the boom switches and master switch 
to ON.

3.

Hold the INC/DEC switch to increase the RPMs. If the motor exceeds the 
desired RPMs, decrease the number by 10 and push INC again.

4.

Decrease the 253 value displayed until the motor runs at the desired RPM.

5.

Enter a number of 10 or greater.

6.

Press the arrow up key to advance to LOW PWM OFFSET 1.

LOW PWM OFFSET 1

Used to set the minimum desired RPM or hydraulic output of the control valve. Used to 
set the zero point or shut-off point of the PWM control valve.

1.

In the DATA MENU, use the arrow keys to advance to LOW PWM OFFSET 
1.

2.

Move the product switch to MAN and the boom switches and master switch 
to ON.

3.

Hold the INC/DEC switch to decrease the RPMs until the motor stops.

4.

Increase the value displayed until the motor runs at the desired RPMs.

5.

Enter a number of 10 or fewer.

6.

Hold the INC/DEC switch to decrease. If the motor does not stop, lower the 
offset number by 10 and push DEC again.

7.

Press the arrow up key to advance to LOW PWM OFFSET 1.

PWM FREQUENCY 

122

Used to enter the coil frequency of the PWM valve type being used. The default 
frequency is 122 Hz.

PRESS ENTER FOR 

DATA-LOCK

Sequence to activate the data lock code, the feature that prohibits data entry without the 
data lock code. The four-digit code must be entered within 15 seconds.

Menu Option

Function

Содержание SCS660M

Страница 1: ...SCS 660 660M Serial Interface for Granular Applications Installation Service Manual...

Страница 2: ...en Industries cannot guarantee the accuracy integrity continuity or availability of the GPS signal from the U S Department of Defense NAVSTAR GPS satellites the OmniSTAR correction service or the WAAS...

Страница 3: ...t Calculation 7 New Leader Mark IV Interface Spreader Constant Values 8 Calculate the Meter Cal Value 9 Calculate the Valve Cal Value 9 Calculate the Rate Cal Value 10 Chapter 3 Calibration Card 11 In...

Страница 4: ...onsole Programming 32 Programming Additional System Data 33 Vol Tank 33 Time and Date 33 Power Down 33 System Features 34 Data Menu 34 Data Logger On Off 35 Self Test Feature 36 Volume Min Rate Fault...

Страница 5: ...Manual No 016 0159 845 iii Testing Flow Meter Encoder Cables 43 Speed Sensor Cables 44 Testing Speed Sensor Extension Cables 44 Troubleshooting 45 Console Issues 45 Rate Control Issues 46 Chapter 8 Re...

Страница 6: ...Table of Contents iv SCS 660 660M Serial Interface for Granular Applications Installation Service Manual...

Страница 7: ...ts for missing or damaged safety labels contact your local Raven dealer When operating the machine after installing the SCS 660 Serial Interface system observe the following safety measures Be alert a...

Страница 8: ...hine manufacturer s approved maintenance instructions When installing AutoBoom hydraulics or performing diagnostics maintenance or routine service ensure that precautions are taken to prevent any fore...

Страница 9: ...erface for Liquid Applications Installation Service Manual P N 016 0159 841 for information on liquid applications The operator sets the target weight per area to be applied and the SCS 660 automatica...

Страница 10: ...Acre km Kilometers kg ha Kilograms per Hectare km h Kilometers per Hour PPK Pounds per 1 000 Square Feet US Volume per Acre mm Millimeters SI Volume per Hectare cm Centimeters TU Volume per 1 000 Squa...

Страница 11: ...his value may be adjusted to optimize the system s performance Wheel Drive Speed Sensors Only Important This procedure should be performed only after the entire system installation is complete This pr...

Страница 12: ...ted every time the gate opening dimensions are changed Formula Calculation First use a tape measure to measure the following dimensions on the machine Gate height GH in inches cm Gate width GW in inch...

Страница 13: ...ecimal in METER CAL 2 Enter a value of 200 in METER CAL 3 Enter 0 in TOTAL VOLUME 4 Run the machine under normal operating conditions collecting a sample large enough to weigh accurately 5 Weigh the s...

Страница 14: ...y dividing 1172 by the exact height of the gate opening For your convenience we have calculated the spreader constant values in one inch increments listed below 2020 Box with 0 192 Chain and Belt Over...

Страница 15: ...shift feature explained in the Decimal Shift Feature section on page 39 Calculate the Valve Cal Value The Valve Cal figure is used to control the response time of the control valve motor to the change...

Страница 16: ...acklash Controls the time of the first correction pulse after a change in correction direction is detected INC to DEC or DEC to INC 1 9 1 Short Pulse 9 Long Pulse Valve Speed Controls the response tim...

Страница 17: ...on Located on the next page is a card that may be used to record the machine s calibration values Write the calibration numbers in pencil so that they may be revised if necessary Cut on the dotted lin...

Страница 18: ...Chapter 3 12 SCS 660 660M Serial Interface for Granular Applications Installation Service Manual...

Страница 19: ...ine on a level surface 2 Select the radar mounting location on the machine considering the following factors The line of sight from the lens to the ground must not be obstructed by structures or tires...

Страница 20: ...Eight Hole Wheel Stud Patterns Optional This section is required only on wheels that do not have pre punched mounting holes If your machine has the pre punched mounting holes proceed to the Mounting t...

Страница 21: ...wheel dividing the wheel into four equal parts 4 Measure in one inch from the rim on each end of the lines and mark the wheel at each point 5 Drill a 1 2 hold on each of the four marks Note The distan...

Страница 22: ...4 1 6 mm 25 mm Make sure the machine s wheels can be turned to the extremes in each direction without the magnets coming in contact with the switch assembly 5 Tighten the mounting hardware to secure...

Страница 23: ...or to the fan sensor bracket using a stainless steel bolt lock washer and nut 2 Mount the fan sensor assembly on the fan sensor mounting tab using a stainless steel bolt lock washer and nut FIGURE 9 F...

Страница 24: ...Locations FIGURE 11 Mounted Bin Level Sensor 1 Use the mounting plate as a template to mark the holes in the appropriate bin sensor mounting location 2 Drill and de burr the mounting holes 3 Align the...

Страница 25: ...r 3 Install the coupler on the end of the encoder 4 Mount the encoder and coupler on the output shaft of the conveyor 5 Install the provided set screws in the coupler to secure the encoder on the outp...

Страница 26: ...iagram 1 Install the control valve with the motor in the upright position in the location appropriate for the machine s configuration Refer to the diagrams above Spinner System Pneumatic System Open H...

Страница 27: ...nnect the white wire on the radar power cable to the white wire on the console control cable 4 Turn the POWER ON OFF switch on the console to OFF 5 Route the red wire on the console control cable to t...

Страница 28: ...Chapter 4 22 SCS 660 660M Serial Interface for Granular Applications Installation Service Manual FIGURE 14 SCS 660 Console Cabling Diagram...

Страница 29: ...4 Manual No 016 0159 845 23 Installation FIGURE 15 SCS 660M Console Cabling Diagram...

Страница 30: ...ystem will not be used for an extended period of time for example two weeks be sure to disconnect the SCS 660 battery wires If the wires are not disconnected and the SCS 660 is only turned OFF the sys...

Страница 31: ...may be necessary to contact Raven Industries with questions about the SCS 660 system The SCS 660 console has an identification label affixed that contains information useful to the Raven customer sup...

Страница 32: ...manual or fully automatic control Manual override control provides the capability of spot application Turns the console power on or off Toggles to variable submenus within a menu except in Data Menu E...

Страница 33: ...rol provides the capability of spot application Turns the console power on or off Displays the rate of application calibration and function data Used to scroll through the menu options in Data Menu To...

Страница 34: ...CAL Target application rate TIME 24 hour clock military time Button Name Function TOTAL AREA Displays total area applied To zero out this figure press ENTER 0 then ENTER in this menu TOTAL VOLUME Dis...

Страница 35: ...he first six steps of this procedure turn the POWER ON OFF switch to the OFF position press CE and hold while turning the POWER ON OFF switch to the ON position to reset the console Refer to the value...

Страница 36: ...ed Note If a second rate is not being used enter the same value that was entered for the Rate 1 Cal The initial console programming is now complete and the flashing CAL in the console s display should...

Страница 37: ...ld be approximately 5280 1000 If the value is between 5260 5300 990 1010 the speed cal value for the machine is 785 200 If the value is any other value use the following formula to recalculate the spe...

Страница 38: ...rs in the display 2 Press ENTER The message CAL SP1 WHEEL DRIVE will appear in the console s display 3 Select the type of sensor being used by pressing the CE button until the desired sensor type appe...

Страница 39: ...The VOL TANK variable will have to be updated each time the tank is refilled Time and Date Note The system runs on a 24 hour clock Therefore for any time after 12 59 pm add 12 hours to the time For ex...

Страница 40: ...r is On the alarm sounds and the display flashes SHAFT 2 if the right shaft should be rotating but is not BIN LEVEL FAULT OFF Turns the bin level fault detector on and off When the fault detector is t...

Страница 41: ...NU use the arrow keys to advance to HIGH PWM OFFSET 253 2 Move the product switch to MAN and the boom switches and master switch to ON 3 Hold the INC DEC switch to increase the RPMs If the motor excee...

Страница 42: ...s R126C D1 total_area field_area CR LF R126C D2 total_volume field_volume CR LF R126C D3 tank_volume distance CR LF Actual Rate R126C AR actual_rate CR LF Time Date R126C TD hr min month day year fiel...

Страница 43: ...nds The alarm may be turned off thru the DATA MENU Low Tank Fault The SCS 660 console alarm will sound if the volume in the tank drops below the value entered into the console The alarm will intermitt...

Страница 44: ...ations to build up pressure when turning the master switch on For best results approach the headlands at consistent speeds while turning all boom sections off Zero Speed Shut Off The Zero Speed Shut O...

Страница 45: ...sition 2 Press CE and hold while turning the POWER ON OFF switch to the ON position Decimal Shift Feature Important When entering data for Rate 1 Cal and Rate 2 Cal remember that 2 GPA 20 lit ha is en...

Страница 46: ...Decimal Place 1 Press the METER CAL button 2 Press the SELF TEST button 3 Enter the flow meter calibration value stamped on the identification tag 4 Press ENTER Unshift the Decimal Place 1 Press the...

Страница 47: ...h boom operates by toggling the boom switches between ON and OFF 10 Hold the INC DEC switch in the INC position for approximately 12 seconds noting the maximum rate value in the display 11 Hold the IN...

Страница 48: ...l performing correctly refer to Chapter 7 Preventative Maintenance and Troubleshooting for possible causes and corrective action 6 At the end of each row switch the boom switches to OFF to shut off th...

Страница 49: ...1 Disconnect the cable from the flow sensor FIGURE 1 Flow Sensor Connector Cable Connection Note If a 5 VDC voltage reading is not present disconnect the speed sensor cable If the flow reading is rest...

Страница 50: ...If the speed reading is restored refer to the Testing Flow Meter Encoder Cables section on page 43 to test the flow meter cables If the speed system is a radar type system the voltage between the 10 o...

Страница 51: ...the field The console display message flashes CAL whenever the vehicle s engine is started Check the battery voltage and connections The console display message flashes CAL whenever the Master switch...

Страница 52: ...CAL figure after testing is complete Issue Corrective Action The RATE displays as 0000 1 Verify that the SPEED is registering correctly If the speed is zero refer to the The SPEED is inaccurate or uns...

Страница 53: ...the valve connector a Turn the Master switch ON b Switch the RATE 1 RATE 2 MAN switch to MAN c Turn the POWER switch ON d Manually operate the INC DEC switch to verify voltage 4 Verify that the valve...

Страница 54: ...Chapter 7 48 SCS 660 660M Serial Interface for Granular Applications Installation Service Manual...

Страница 55: ...CHAPTER 8 SCS 660 660M Serial Interface for Granular Applications Installation Service Manual 49 Chapter8Replacement Parts...

Страница 56: ...Chapter 8 50 SCS 660 660M Serial Interface for Granular Applications Installation Service Manual...

Страница 57: ...nformation Electrical 2 Hydraulics 2 Initial System Setup and Testing Initial Setup 41 Initial System Field Test 41 Installation Console and Cabling 21 Control Valve 20 Alternate Bypass Line Plumbing...

Страница 58: ...Index 52 SCS 660 660M Serial Interface for Granular Applications Installation Service Manual...

Страница 59: ...Coverage Period How Can I Get Service What Will Raven Industries Do What is not Covered by this Warranty Bring the defective part and proof of purchase to your Raven Dealer If your Dealer agrees with...

Страница 60: ...reserved under copyright laws Raven Industries Toll Free U S and Canada 800 243 5435 Applied Technology Division or Outside the U S 1 605 575 0722 P O Box 5107 Fax 605 331 0426 Sioux Falls SD 57117 5...

Отзывы: