13
Valve Backlash Digit
Valve Backlash Digit
Valve Backlash Digit
Valve Backlash Digit
Valve Backlash Digit
Controls the time of the first correction pulse
after a change in correction direction is detected.
(INC to DEC
-or-
DEC to INC).
Range: 1 to 9
1-Short Pulse
9-Long Pulse
Valve Speed Digit
Valve Speed Digit
Valve Speed Digit
Valve Speed Digit
Valve Speed Digit
Controls response time of Control Valve motor.
CAUTION:
CAUTION:
CAUTION:
CAUTION:
CAUTION:
Running the Control Valve too fast will
cause the system to oscillate.
C-Sd Valve Control
Range:
1 to 9
1-Slow
9-Fast
C-F or C-FC Valve Control
Range:
0 to 9
0-Fast
9-Slow
Brake Point Digit
Brake Point Digit
Brake Point Digit
Brake Point Digit
Brake Point Digit
Sets the percent away from target rate at which the
Control Valve motor begins turning at a slower
rate, so as not to overshoot the desired rate.
Range: 0 to 9
0 = 5%
1 = 10%
9 = 90%
Dead-Band Digit
Dead-Band Digit
Dead-Band Digit
Dead-Band Digit
Dead-Band Digit
Allowable difference between target and actual
application rate, where rate correction is not
performed.
Range: 1 to 9
1 = 1%
9 = 9%
4.
CALCULATING "VALVE CAL"
The initial Control Valve calibration number for VALVE CAL is 2123 for C-Sd
(standard valve), or 743 for C-F (fast valve) and C-FC (fast close valve). The
VALVE CAL number is used to control response time of the Motor Control to the change
in vehicle speed. After operating the system, you may desire to refine this number.
See definitions below:
For FAST VALVE
FAST VALVE
FAST VALVE
FAST VALVE
FAST VALVE (C-F or C-FC):
For STANDARD VALVE
STANDARD VALVE
STANDARD VALVE
STANDARD VALVE
STANDARD VALVE (C-Sd):