CONSOLE CALIBRATION
1.
CALCULATING "METER CAL"
The Flow Meter calibration number is stamped on the tag attached to each Flow Meter.
This number is to be used for gallons [liters] per application.
To convert original METER CAL from gallons to desired units of measure, see METER
CAL CONVERSIONS on
page 3
. Write down this calibration number for future reference
when programming the Console.
2. CALCULATING "LIQ CAL"
Determine the application rate at which your chemical should be applied. Consult
with your Dealer to ensure your spray nozzles are capable of applying at this rate.
In determining which spray nozzles to use, you must know:
1) Nominal Application Pressure
___PSI [kPa]
2) Target Application Rate
___GPT [lit/MT]
3) Granular Application Rate
___(lb/mile) [kg/km]
4) Target Speed
___MPH [km/h]
5) Number Of Nozzles
___
From this information you can than calculate the volume per minute per nozzle as
follows:
GPM
=
GPT x (lb/mile) x MPH
120,000 (No. of nozzles)
lit/min
=
lit/MT x [kg/km] x [km/h]
60,000 (No. of nozzles)
Use GPM [lit/min] and pressure to select appropriate tip from tip chart.
EXAMPLE:
EXAMPLE:
EXAMPLE:
EXAMPLE:
EXAMPLE:
1) Application Pressure
30 PSI [200 kPa]
2) Target Application Rate
7.0 GPT [30 lit/MT]
3) Granular Application Rate
2900 lb/mile [800 kg/km]
4) Target Speed
6.2 MPH [10.5 km/h]
5) Number of nozzles
3
US UNITS
US UNITS
US UNITS
US UNITS
US UNITS
GPM = 7.0 GPT x 2900 lb/mile x 6.2 MPH = .35 GPM
120,000 (3)
SI UNITS
SI UNITS
SI UNITS
SI UNITS
SI UNITS [lit/min] = 30 lit/MT x 800 kg/km x 10.5 km/h = 1.40 lit/min
60,000 (3)
Using CAPACITY = .35 GPM [1.40 lit/min] and pressure = 30 PSI [200 kPa] you would
select tip number XR8004 from the chart on next page, since it comes closest to
providing the desired output.
Содержание DCS 300
Страница 1: ...DCS 300 INSTALLATION AND SERVICE MANUAL ...
Страница 3: ......
Страница 4: ...Manual Rev C DCS 300 10 97 Order 50 10 28 97 016 0159 577 ...
Страница 11: ...7 BATTERY CONNECTIONS FIGURE 4 FIGURE 4 FIGURE 4 FIGURE 4 FIGURE 4 ...