3
Manual No. 016-1001-063 Rev. E
11
ACCUBOOM INSTALLATION
11. Connect the appropriate jumper cable to the AccuBoom harness. Refer to the following table to choose the
jumper cable.
SWITCHING FROM LIQUID APPLICATION TO SPINNER SPREADER CONFIGURATION -
TERRAGATOR ONLY
When switching from a liquid application to a spinner spreader application on a TerraGator, AccuBoom must be
removed from the system before the machine will operate correctly. Complete the steps in this section to convert
the TerraGator system from a liquid to a spinner spreader application.
1. Disconnect the AccuBoom harness cable from the TerraGator Section T connection in the access panel and
reconnect the Section T together.
2. Disconnect the AccuBoom Logic Power connector from the TerraGator Aux Pwr connector in the access panel.
3. In the Viper Pro Miscellaneous Settings screen, change the AccuBoom node from Combo to AccuBoom Only.
NOTE:
Repeat the steps above in reverse order to convert the system from a spinner spreader application to
a liquid application.
INSTALL THE ACCUBOOM NODE
NOTE:
The AccuBoom node (P/N 063-0172-714) is sold separately. Contact your local Raven dealer for
ordering information.
TABLE 1.
Application
Jumper
RoGator Liquid
Liquid Jumper
RoGator AirMax 180
AirMax 180 Jumper
TerraGator Liquid
Liquid Jumper
TerraGator AirMax/AirSpread
Dry Jumper
TerraGator Spinner Spreader
Remove AccuBoom and refer
to the next section