- The pellet tank is empty.
- Check for the presence of pellets in the
container. Top up, if necessary.
- The gear motor is not loading pellets
- Empty the tank to see if there are any objects
inside that may prevent the proper operation of
the auger.
- Not enough pellets loaded
- Regulate pellets setting from “SET AIR/
PELLETS”
- If the problem persists, contact the Support
Service Support
AL 07 RESET THERMAL BREAKER / PELLET
DOOR OR GATE OPEN
- The manual reset thermostat has tripped
connected to the hopper (RESET THERMAL
BREAKER /
Pellet door or gate is open
- Reset the thermostat by pressing the button on
the back of the stove or close the doors.
- Combustion in the grate is not optimal due
to the fact that the grate is clogged or the inner stove
ducts are clogged. (RESET THERMAL BREAKER)
- Switch off the stove, clean the brazier and the
tube bundle and adjust the combustion setting
the Pellet/Air values
- Contact the Support Service
AL 08 DEPRESSURIZATION
- The flue is blocked.
Check the flue is free and clean
- The vacuum meter is faulty.
- Contact the Support Service
AL 12 FUME EXHAUST SYSTEM
FAILURE
- T he fume exhaust system has a loss of
performance due to fan obstruction or voltage drop.
- Contact the Support Service
AL 14 SCREW PHASE
- No cable connection to power the gear motor
of the auger
- Contact the Support Service
AL 15 AUGER TRIAC
- An internal part of the electronic board that controls
the pellet infeed screw is faulty.
- Contact the Support Service
- Possible voltage drops or incorrect input voltage
stove inlet
- Check the mains voltage.
AL 17 NO FLOW
(only if the RDS system is provided)
-
The flow meter does not measure inlet air flow
- Check if the ash pan and door are
closed correctly and check if the air inlet pipe is
obstructed
.
- If the problem persists, contact the Support
Service
Positions of the switch
protected by a screw cap and
of the reset safety thermostat
located on the
side.
Содержание RBV 8008
Страница 2: ...RBV 8008 RBV 8010 MANUALE D USO E MANUTENZIONE...
Страница 3: ......
Страница 7: ...RBV 8010 RBV 8008 RBV 8010...
Страница 9: ......
Страница 46: ......
Страница 47: ......
Страница 48: ......
Страница 50: ...RBV 8008 RBV 8010 MANUEL D UTILISATION ET D ENTRETIEN...
Страница 51: ......
Страница 55: ...RBV 8010 RBV 8008 RBV 8010...
Страница 56: ......
Страница 57: ......
Страница 95: ......
Страница 96: ......
Страница 98: ...RBV 8008 RBV 8010 USE AND MAINTENANCE MANUAL...
Страница 99: ......
Страница 103: ...RBV 8010 RBV 8008 RBV 8010...
Страница 104: ......
Страница 105: ......
Страница 143: ......
Страница 144: ......
Страница 146: ...RBV 8008 RBV 8010 BEDIENUNGS UND WARTUNGSHANDBUCH...
Страница 147: ......
Страница 151: ...RBV 8010 RBV 8008 RBV 8010...
Страница 152: ......
Страница 153: ......
Страница 191: ......
Страница 192: ......
Страница 194: ...RBV 8008 RBV 8010 MANUAL DE USO Y MANTENIMIENTO...
Страница 195: ......
Страница 199: ...RBV 8010 RBV 8008 RBV 8010...
Страница 200: ......
Страница 201: ......
Страница 238: ......
Страница 239: ......
Страница 240: ......
Страница 242: ...HANDLEIDING VOOR GEBRUIK EN ONDERHOUD RBV 8008 RBV 8010...
Страница 243: ......
Страница 249: ......
Страница 290: ......
Страница 291: ......
Страница 292: ......