background image

18

User’s manual HANDHELD TOUCH RADIO

User’s manual HANDHELD TOUCH RADIO

Pag.20 

Pag.21 

Vers. 01 of:07.04.14

Vers. 01 of:07.04.14

2

3

1

2

3

1

FIRST INSTALLATION?

PRESS THE KEY RADIO 

ADJ ON THE STOVE

YES

MENU

USER

USER

SETTINGS

SETTINGS

DATE-TIME

USER

COMFORT CLIMA

MANUFACTURER 

ENGINEER

ENABLE EXT. TH.

CONTRAST

FW VERSION

ADJUST

LANGUAGE

SCREW FEEDING

CHRONOTHERMOSTAT

AIR-PELLET SET

STOVE STATE

Handheld touch radio initialization 

In order  to operate correctly, the handheld set should be interfaced with the electronic board installed inside the stove.  For this  

reason, on display appears the following message:  

If the handheld set is used for the first time, select 

YES

 using the selection keys and confirm with the dedicated key. 

On the display of the handheld set appears the following:  

Hold down for a few seconds the button of radio communication (RADIO ADJ) of the PCB, located on the back of the stove, to  

initialize the device.  

The flashing yellow LED indicates that the circuit board is waiting to receive the signal from the handheld set. 
By pressing the enter key on the handheld set, the components start communicating with each other. A check sign on the display,  

accompanied by a sound signal, shows that the initialization of the handheld set has been completed sucessfully 

.  

When you replace the batteries, you do not have to run the initialization procedure of the handheld set. In this case, when  

on display appears the message “FIRST INSTALLATION ?”, select 

NO and press the confirmation key.  

Description of the display 

The display of the handheld set is described below (in stand-by mode):  

After 5 minutes of inactivity, the display of the handheld set turns dark, switching to “SLEEP” mode, while maintaining the  

radio connection with the stove. By pressing the key ON/OFF, the display becomes active again. 

The first pressure of any key with the display active, lights up its backlight, but it is not, however 

considered a   command.  

The display is subdivided into three parts:  

1. It shows the current room temperature measured by the handheld set. Moreover, if you press the DOWN scroll key you will 

display the temperature settings that can be changed using the two UP/DOWN keys. Any change made is confirmed automatically 

within 3 seconds from the change or by pressing the confirmation key. A sound signal indicates that the change has been con-

firmed. 

In the inactive phases (combined with the 3rd part of the display) indicates the state of the stove.  

In the active phases, it indicates the operating power of the stove. 

In addition, by pressing the DOWN scroll button, you can display the power settings, that can be edited using the two scroll  

keys        

UP/DOWN: The confirmation of any change takes place automatically within 3 seconds from the change or by pressing the con-

firmation key. A sound signal indicates that the change has been confirmed.  

Time and date setting 

Below are given the steps for accessing the relative menu.  

Press the key  “access menu” to 

access  

the  

MENU page  

Press the key  

“confirm” to  
access the  

SETTINGS  

page  

Press the key  

“confirm”  

to access the  

USER page  

Press the key  “con-

firm”  

to access the  page 

DATE-TIME  

Press the key “selection” for  

“selection”  

to switch to the second page  

of USER MENU and select  

SETTINGS.   

Press the increase key to change every single value 

Press the increase key to change every single value 

Press “confirm” to confirm the settings and switch to the next 

value. 

By pressing the key “back” for several times you will display 

the  stand-by page.  

6.5  Time and date setting

Содержание Dual 7

Страница 1: ...nual PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS WOOD PELLET FIRE FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH Contact your l...

Страница 2: ...echnical programming and individualised air pressure adjustments to ensure it will operate safely and ef ciently and to avoid possible damage to the re or the home Installation of the Dual 7 Wood Pell...

Страница 3: ...s 8 2 8 Safety Devices 8 2 9 Responsibilty 8 2 10 Spare Parts 8 3 What are Wood Pellets 9 4 The Components of the Stove 9 4 1 Pellet Combustion 10 5 Maintenance and Cleaning 11 5 1 Cleaning the surfac...

Страница 4: ...f the Display 16 6 5 Time and Date Settings 17 6 6 Loading the Auger 18 6 7 Setting Operating Temperature and Power 19 6 8 Turning the Device on 19 6 9 Operating Phases of the Stove 20 6 9 1 Alarms 28...

Страница 5: ...f fuel used IMPORTANT The above values were found during testing and may vary with the fuel type climate and installation style Testing Standard Description Class I IP 20 AS NZS 5078 2007 Appliance AS...

Страница 6: ...l l a t s n I r e l a e d Solutions Fire personnel who must give the purchaser a declaration of conformity of the appliance and who will installed It is also necessary to take into consideration all t...

Страница 7: ...circulation 3 Check clearances to combustibles refer page 37 2 3 Ash The ash content of the fuel and operation of your stove will directly determine the frequency of cleaning The use of high ash fuel...

Страница 8: ...ponsibility due to Poor maintenance Failure to observe the instructions in the manual Use not compliant with the safety instructions Installation that is not compliant with the regulations in force in...

Страница 9: ...d and can be 1 5 twice greater than that of natural wood The diameter of the cylindrical rods is 6 10 mm and their length can vary between 10 and 50 mm Their weight is equal to about 650 kg m Due to t...

Страница 10: ...d Then adjust set pellet air increasing the air percentage from 0 up to 5 If this doesn t work try increasing the loading quantity of the pellet from 0 up to 5 to reach the flame condition shown in pi...

Страница 11: ...n i m i t r o f s i h t n o i t a r e g n i k r o w ho l c s t e s y r e v e e m i t e h t e v o t s s i d e n r u t n o 2 s n o i t a t o r y b t l u a f e d d n a r e t f a 8 s r u ean e h T r e 0 6...

Страница 12: ...ime the stove is used and the type of pellet used To access the drawer open the door 2 figure see drawer ashes the extract and 1 figure see N B The operation must be carried out when the stove is cold...

Страница 13: ...1 e smontare i laterali come in fig 2 per accedere alle botole di ispezione Le piastre sono guarnizionate pertanto prima di rimontare le botole assicurarsi che le guarnizioni che permettono l ermetici...

Страница 14: ...the iron slide 2 as shown This helps to prevent the pellet bag to touch the cast iron parts Lid of pellet tank Iron slide 1 2 5 8 How to load pellet 5 9 How to remove Firex 7 Opuscolo dedicato modello...

Страница 15: ...FRQWDFW ZLWK KRW VXUIDFHV Manuale utente PALMARE IDRO TOUCH RADIO Pag 22 Vers 01 del 07 04 15 Wiring RQQHFW WKH SRZHU FRUG WR WKH EDFN RI WKH VWRYH DQG WKHQ WR D ZDOO VRFNHW 7KH 2 VZLWFK LQ WKH JXUH V...

Страница 16: ...VLJQDO IURP WKH KDQGKHOG VHW SUHVVLQJ WKH HQWHU NH RQ WKH KDQGKHOG VHW WKH FRPSRQHQWV VWDUW FRPPXQLFDWLQJ ZLWK HDFK RWKHU FKHFN VLJQ RQ WKH GLVSOD DFFRPSDQLHG E D VRXQG VLJQDO VKRZV WKDW WKH LQLWLDOL...

Страница 17: ...andheld set Moreover if you press the DOWN scroll key you will display the temperature settings that can be changed using the two UP DOWN keys Any change made is confirmed automatically within 3 secon...

Страница 18: ...e Press the key confirm to access the SETTINGS page Press the key confirm to access the USER page Press the key con firm to access the page DATE TIME Press the key selection for selection to switch to...

Страница 19: ...le the rotation of the auger The appearance of the message ADJUST THE RDS SYSTEM indicates that the initial parameter testing procedure and calibration has been unsuccessfully This indication does not...

Страница 20: ...hermostat optional this must be connected to the appropriate connector on the rear side of the stove and you will have to activate the reading in SETTINGS EN ABLE THERMOSTAT On display appears the wri...

Страница 21: ...TA 5 For example with the room temperature at 21 C the stove switches of f when this temperature is reached and restarts when the temperature reaches 15 C 21 C 5 C 0 5 C tolerance You can also activat...

Страница 22: ...nge the quantity of pellet loaded in the brazier and the air inflow The stove is tested and inspected with DIN PLUS certified pellets If using another type of pellets or uncertified pellets fuel may n...

Страница 23: ...of the stove useful for service during inspection Actual flow Fume extractor revolutions Fume temperature Stove state To exit the STOVE STATE page and return to Stand by page press the button repeated...

Страница 24: ...of the information shwon on the handheld set The value can vary from 0 to 100 50 with respect to Settings Firmware version Press the key confirm to access the SETTINGS page Press the key selection to...

Страница 25: ...t on the stove If the AUTO function is not enabled the fan operation is not depending on stove s installed power except for the cases in which the flame switches to modulation mode and the heat exchan...

Страница 26: ...e WAITING FOR FLAME The pellets ignite and take advantage of the heat in the intake air that passes through the incandescent heater tube FLAME PRESENT The flame is visible in the grate AREAS The stove...

Страница 27: ...quest from ECO STOP mode coincides with an automatic switch off condition from the TIMER the stove turns on ensuring total cleaning of the brazier before switching to FINAL CLEANING INFEED SCREW OVERF...

Страница 28: ...setting from SET AIR PEL LETS If the problem persists contact the Support Service Support AL 07 RESET THERMAL BREAKER PELLET DOOR OR GATE OPEN The manual reset thermostat has tripped connected to the...

Страница 29: ...efore switching on the stove it is necessary to check that the brazier is clean and so that they are always excellent combustion thus avoiding any overheating that may cause changes in the color of th...

Страница 30: ...30 38 4 Maintenance Record DATE WORK CARRIED OUT SIGNATURE 40 7 Maitenace record...

Страница 31: ...al service fees may apply if you are seeking warranty service from a dealer other than the dealer from whom you originally purchased the product Check with your dealer in advance for any costs to you...

Страница 32: ...let Solution e r i F s approved venting components hearth components or other accessories used in conjunction with the appliance Any part of a pre existing replace system Pellet Ravelli i t u l o S on...

Страница 33: ...wood pellet re purchase and attach the receipt and any other documents business cards from the retailer that sold you the re Name of Store where Pellet re was purchased Date of Purchase Amount Paid Pa...

Страница 34: ...ioning the stove 38 2 6 Location of a power source 38 2 7 Internal Standard Flue Kit 50SBD N 39 2 8 External Standard Flue Kit 51ita 40 2 9 Seismic Restraint 41 2 10 Fixing to Timber Floor Framing 41...

Страница 35: ...ter of smoke exhaust duct mm 80 Min max 1040 502 561 power calorofic kW 3 3 6 7 Min max hourly consump tion of pellets Kg h 86 0 95 1 5 Electrical power absorbed during operation W 240 Supply V Hz 220...

Страница 36: ...down completely meaning the likelihood of any hot embers or burning fuel escaping from the combustion chamber is extremely minimal Therefore a 150mm forward projecting floor protector will be suffici...

Страница 37: ...H A E External Flue J J F B I F E 7 Dual Pellet Fire Clearance to Combustibles B C A E D G F B F G E Internal Flue Location Dimension mm A B 150 C D E 100 F 0 1 0 G H I J 250 50 n a 50 0 1 0 50 25 Fr...

Страница 38: ...pellet fire door 7 Dual has been Safety Tested to AS NZS 2001 2918 using the Davins manufactured flue Test Report ARS 05 1185 Installation is not exclusive to these nominated kits though alternative...

Страница 39: ...6m The visible flue is finished in black and the ceiling plate is white The support angles for securing the liner to the ceiling are not shown Kit is supplied in a carton Heat resistant floor protect...

Страница 40: ...and penetrating the soffit The overall height of the flue is 3 6m All visible flue has a galvanised finish and can be powdercoated on request Kit is supplied in a carton Note The Davin 51 External St...

Страница 41: ...5 shall be provided 9 2 Installation 7 Dual should be installed in a centrally located position within the home This will assist the appliance to perform to the level required Dual As heats space by c...

Страница 42: ...42 1 2 x 4 2 12 How to mount the side panels 10 Opuscule d di au mod le Dual 7 Brochure for Dual 7 model Brosch re f r Modell Dual 7 2 3 x 4...

Страница 43: ..._________________ Phone ________________________________ Model __________________________ Serial Number ____________________ Date of Purchase __________ dd mm yy Date of Installation _________ dd mm y...

Страница 44: ...44 38 4 Maintenance Record DATE WORK CARRIED OUT SIGNATURE 40...

Страница 45: ...peration of my Pellet Fire I understand that warranty conditions require an authorised Pellet Fire Solutions Installer to complete the installation Signed Date Installation Details Pellet Fire Model S...

Отзывы: