INSTALLATION MANUAL
–
RAVAS-
SafeLoad
30
90
Recover factory
default parameter
settings only, based
on actual P01 setting
91
Recover initial
parameter se
calibration from
backup (P94)
92
Recover last (re-
)calibration only. And
convert calibration to
the actual set startup
unit
93
Read out last 50
error messages(with
timestamp)
00-00
Display will show [WAIT] until all
errors are completely loaded.
94
Backup initial
parameter se
calibration
00000
95
Measurement on/off
on
On; OFF
96
F-key activ
OFF
On; OFF
97
Key test function
(Buzzer and nr)
99 Software
version
(last available
version)
0.34
Note 1: P_005 has 6 settings for the maximum capacity. 3 in the lowest position and 3 in the
highest position of the forks. Use the forklift diagram as reference. If the system has no
different hydraulic pressures for lower and higher mast stages, the settings for H1/H2/H3
have to be set to the same value as L1/L2/L3.
Attention: The display will show [L] and the left horizontal bar will light up“L1”. For “L2” the
display will show [L] and the middle horizontal bar will light up. Etc.
NOTE: the setting of this parameter has no influence on the calibration.
Example forklift diagram
Select this value (1800) for setting the
maximum capacity in the lowest position
[L1=500], select 1620 for position L2=600
and select 1470 for position L3=700 (in this
example)
Preferably set this value (1200) for the
maximum capacity in the highest position
[H1=500], select 1080 for position H2=600
and select 980 for position H3=700 (in this
example)