Anchors will not stay tight. 1.Latch shafts rusted. (Usually
occurs on outside installations or in
high humidity areas such as vehicle
wash bays.)
2.Latch spring broken.
3.Latch cable needs adjustment.
1.Relocate lift using a new bit to
drill holes. Reference installation
instructions for minimum spacing
requirements.
2.Break out old concrete and repour
new pads for lift per lift installation
instructions.
Locking latches do not
engage.
1.Latch cable is broken.
2.Cable is off sheaves/upper guides.
3.Latch cable is loose.
1. Remove covers, oil latch mechanism.
Actuate latch release handle several
times to allow oil to coat shaft.
2.Replace broken spring.
3.Adjust clamp at cable end per lift
installation instructions.
Locking latches do not
disengage.
1.Low oil level.
2.Air in hydraulic lines/cylinder.
1.Replace cable.
2.Check position of cable on sheaves/
upper guides; adjust cable tension.
3.Adjust cable tension.
Lift stops short of full rise
or chatters.
Lift stops short of full rise or chatters. 1.Fill tank to proper level with ISOVG32
Hydraulic Oil or Dexron III ATF.
2.Bleed lift per installation instructions.*
*Lifts with bleeders only.
Lift will not raise off of
latches
Motor, pump, or cylinder failure
1.Contact lift manufacturer's Customer Service.