QuickLock Operator Manual
2
QuickLock Operator Manual
– Version 15.07.01
IMPORTANT DISCLAIMER:
This manual is subject to change without notice. Updates can be obtained online at
. This manual does not guarantee the product will work
properly. The manual cannot take the place of your own experience or practical instruction by
the manufacturer. Contact a RAUSCH Certified Installer to ensure proper installation. The
following are important disclaimers to consider before using the QuickLock system.
1.
QuickLock installations are to be performed only by trained and qualified personnel, using
adequate and safe equipment.
2.
Read and follow the instructions, as described in this manual before attempting installation.
3.
Prior to beginning the installation, verify that all the equipment and components involved are
undamaged and in proper working condition.
4.
The use of equipment other than a certified
Rausch
packer and components will void the
functionality warranty. Using a Rausch QuickLock packer for non-OEM installations/sleeves
risks damages to the device or potentially injuring the operator, and voids all product
warranties.
5.
Pressure gauge
must have the proper range setting (0
– 70psi).
6.
NEVER
exceed the maximum packer pressure as indicated in the manual.
7.
NEVER
inflate the packer outside of a pipe
– serious bodily injury or death may occur!
8.
QuickLock is designed for and must only be used in municipal sewer, storm sewer and potable
water environment. For use in potable water, a special rubber gasket is required. For all other
applications, please consult Rausch prior to use.
9.
Do not
use QuickLock in broken pipes with protruding objects.
10. Verification of lines
inner diameter / I.D. must be known
as accurate as possible in order to
ensure the correct sleeve is used. Refer to the Data Sheet at the end of this manual.
11. If after reading this manual you have any questions or concerns, please contact
Rausch USA
.