Alarm messages and possible causes
6
100
12
Transmission fault. No
RS232 connection
An error has occurred during data transmis-
sion to the control unit.
The data have not been transmitted.
14
Error by setting TELIMAT.
Alarm for the TELIMAT sensor.
This error message is displayed if the TELI-
MAT status cannot be detected for more
than 5 seconds.
15
Memory full. Delete one pri-
vate fertiliser chart.
A maximum of 30 fertiliser charts can be
saved.
No additional saving possible
16
Approach drop point
Yes = Start
For machines with electrical drop point ac-
tuators: Safety query before the drop point
is automatically approached.
Drop point can be set in the
Fertiliser
settings
menu.
Fast emptying.
17
Error by setting drop point.
The actuator for the drop point setting can-
not reach the target value to which it is to be
moved.
Blockage.
No position feedback.
18
Drop point blocked
Actuator overloaded.
19
Defect by setting drop point. Actuator defective.
20
Error on LIN bus participant:
[Name].
Communication problem.
Remove actuator.
Cable breakage.
21
Spreader overloaded!
The mineral fertiliser spreader is overloaded.
Too much fertiliser in the hopper
23
Error by setting TELIMAT
The TELIMAT setting actuator cannot reach
the target value it is to be moved to.
Blockage.
No position feedback.
24
Error by setting TELIMAT
Actuator overloaded.
25
Defect by setting TELIMAT
TELIMAT actuator defective.
32
Externally controlled parts
may move. Risk of injury
through squeezing and
shearing!
Direct ALL persons out of the
danger zone. Read the in-
struction manual.
Confirm with ENTER
If the machine control unit is activated, com-
ponents may move unexpectedly.
Follow the displayed instructions only if
all risks have been eliminated.
No. Message on display
Meaning
Possible cause
Содержание QUANTRON-A AXIS-M 20 Q
Страница 6: ...Table of Contents IV...
Страница 10: ...User instructions 1 4...
Страница 16: ...Layout and function 2 10 Figure 2 5 Control unit display example MDS operating screen 3 11...
Страница 24: ...Layout and function 2 18...
Страница 92: ...Operation QUANTRON A 4 86...
Страница 104: ...Spreading operation with the QUANTRON A control unit 5 98...
Страница 114: ...Index D...
Страница 116: ......