Operation QUANTRON-A
43
4
4.6.3
Flow factor
The flow factor ranges between
0.2
and
1.9
. The following applies for consistant
basic settings (km/h/, working width, kg/ha):
If the flow factor is
increased
, the application rate is
decreased
.
If the flow factor is
decreased
, the application rate is
increased
.
An error message is displayed if the flow factor is outside the preset range. See
6: Alarm messages and possible causes, page 99
. If spreading organic fertiliser
or rice, the minimum factor has to be reduced to 0.2. Otherwise the error mes-
sage will be displayed constantly.
If the flow factor is known from earlier calibration tests or from the fertiliser chart,
it can be entered
manually
in this menu.
The
M EMC function
determines the flow factor specifically for each spreading
side. Therefore, no manual input is required.
Entering the flow factor:
1.
Open the
Fertiliser settings > Flow factor
menu.
The
currently applied
flow factor is displayed.
2.
Enter the new value in the input field.
See chapter
4.13.2: Entering values with the cursor keys, page 84
3.
Press the
Enter key
.
The new value is saved in the control unit.
NOTICE
Via the
Calibration
menu, the flow factor can be determined and entered using
the QUANTRON-A control unit. Refer to chapter
NOTICE
The flow factor calculation depends on the operating mode used. For further in-
formation on the flow factor, refer to chapter
.
NOTICE
If the fertiliser is not listed in the fertiliser chart, enter a flow factor of
1.00
.
In the
AUTO km/h
and
MAN km/h
operating modes, we highly recommend car-
rying out a
calibration test
in order to be able to accurately determine the flow
factor for this fertiliser.
NOTICE
AXIS-M EMC (+W) only
We recommend displaying the flow factor in the operating screen. This allows
you to monitor the mass flow control during spreading. Refer to chapter
Display configuration, page 72
and chapter
Содержание QUANTRON-A AXIS-M 20 Q
Страница 6: ...Table of Contents IV...
Страница 10: ...User instructions 1 4...
Страница 16: ...Layout and function 2 10 Figure 2 5 Control unit display example MDS operating screen 3 11...
Страница 24: ...Layout and function 2 18...
Страница 92: ...Operation QUANTRON A 4 86...
Страница 104: ...Spreading operation with the QUANTRON A control unit 5 98...
Страница 114: ...Index D...
Страница 116: ......