CAUTION!
Risk of injury due to automatic adjustment of the drop point
With
AXIS EMC
, the Approach drop pointYes = Start alarm message appears. When you press the
Start/Stop function key, the drop point automatically moves to position 0. After the calibration, the
drop point automatically moves to the preset value again. This may cause injury and property
damages.
▶
Before pressing the Start/Stop key, ensure that
nobody
is present in the hazard zone of the
machine.
Before storage, you can completely empty the hopper of your machine via the machine control unit.
Complete discharge:
u
Select both sections.
u
Press
Start/Stop
.
Both metering slides open.
The drop point moves to the left and to the right, to the value 0.
u
Press and hold the Complete discharge button.
The drop point moves between the values 9.5 and 0 to allow the fertilizer to flow out.
u
Release the
Complete discharge
button.
The left and right drop point moves back to the value 0.
u
Press
Start/Stop
.
The drop point automatically moves to the pre-set value.
4.7
System/Test
In this menu, the system and test settings for the machine control unit can be configured.
u
Access the menu Main menu > System / Test.
4. Operation
AXIS EMC ISOBUS
5902180-h-gb-
55
Содержание AXIS EMC ISOBUS
Страница 6: ...6...
Страница 21: ...2 4 Structural menu overview AXIS M EMC 2 Layout and function AXIS EMC ISOBUS 5902180 h gb 21...
Страница 22: ...AXIS H EMC 2 Layout and function 22 5902180 h gb AXIS EMC ISOBUS...
Страница 70: ...Fig 33 Button functions Level 1 Fig 34 Button functions Level 2 4 Operation 70 5902180 h gb AXIS EMC ISOBUS...
Страница 102: ......