![Rauch AERO ISOBUS Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/rauch/aero-isobus/aero-isobus_complementary-instructions_3794800048.webp)
Status bit
Description
Possible cause
1
No speed signal
•
Hydraulics off
•
Motor is not rotating.
•
Speed sensor not connected or defective
•
Broken cable or short circuit
2
Defect on an proportional valve
•
Proportional magnet coil not connected
•
Cable breakage
•
Coil defective
3
Speed cannot be adjusted
•
Problem on hydraulics
•
Constant current/PowerBeyond mixed up
•
Incorrect setting on LS pressure regulation
switching valve
•
Oil too cold
•
Pump not enough output, …
4
Metering valve rotates without
being actuated.
•
Problem on hydraulics/electrical system
•
Back-pressure in the system
•
Short circuit
5
Maximum speed not reached during
calibration
Metering valve did not reach 100 rpm.
•
Mostly in conjunction with bit 3
6
reserved
Contact your Customer Service department or
specialist workshop.
7
Metering unit not calibrated
Contact your Customer Service department or
specialist workshop to execute the calibration.
8
Calibration in progress
The system is currently being calibrated.
Check to make sure that all cables and other lines (sensors, etc.) are connected correctly and in
proper condition. For any other source of error, contact the Customer Service department and
provide the error code.
Resetting the revolutions:
u
Press the Reset button.
The speed of the metering valves is now set to 0 rpm.
4. Operation
48
5903001
AERO ISOBUS
Содержание AERO ISOBUS
Страница 16: ...2 3 Structural menu overview 2 Layout and function 16 5903001 AERO ISOBUS...
Страница 54: ...Fig 30 Button functions Level 1 Fig 31 Button functions Level 2 4 Operation 54 5903001 AERO ISOBUS...
Страница 62: ...For this purpose follow the instructions on screen 6 Alarm messages and possible causes 62 5903001 AERO ISOBUS...
Страница 65: ......