u
Access the menu Test/diagnosis > Metering RPM.
The display shows the status of the metering units.
The number of sections depends on the machine type.
•
If your machine only has 4 sections/metering units, sections 5 and 6 are irrelevant.
Fig. 24: Test/diagnosis; Example: Metering RPM
[1]
Number of sections/metering units
[2]
Display of the target speed that has been
entered
[3]
Display of the actual speed
[4]
Revolution counter
[5]
Resetting the revolution counter
[6]
Metering module version
[7]
Error display via status bits
u
The metering module version [6] must display at least 20308. This corresponds to version
2.03.08.
Please contact your dealer of your specialist workshop if the version is not correct.
The error/status bits are displayed for each metering unit in line Err [6]. If no error is present and no
calibration is executed, the line is blank. Several errors can be displayed at the same time. The
various states are described in the table below.