A)
SE1
B)
SE1
SE2
SE3
SE4
SC
SE5
SHO
SE6
SE 7
SE 8
since C1-
06-04
SE 9, 10, 11
SE 12,13, 14
SE 15,16, 17
Press time key and adjust displayed rpm with timer dial
SE15 = MIN rpm; SE16 = Start rpm; SE17 = MAX rpm
Always check CO
2
values in function test
Press time key and select "on" or "oFF" in with timer dial
Press time key and select new gas type with timer dial
NOTE: C0
2
values must be manually controlled/adjusted in function test
Corresponding gas blower speed is automatically adjusted
Press time key and select "ST" for steam, "HA1" for hot air top or
"HA2" for hot air bottom (only 201/202) with timer dial;
Average lenght in mm of CO
2
crew on gas valve is shown in timer display
Adjusting speed of
blower motor hot air, bottom
(+ / -10%)
(After blower speed adjustment indicated gas type (SE6) gets suffix "-S")
Press time key and adjust displayed rpm with timer dial
SE9 = MIN rpm; SE10 = Start rpm; SE11 = MAX rpm
Always check CO
2
values in function test
Adjusting speed of
blower motor steam
(+/ -10%)
(After blower speed adjustment indicated gas type (SE6) gets suffix "-S")
Adjusting speed of
blower motor hott air, top
(+ / -10%)
(After blower speed adjustment indicated gas type (SE6) gets suffix "-S")
Adjustment of installation altitude above sea level
0-500m (0-1640ft), 500-1000m (1640-3280ft),
1000-1500m (3280-4920ft), 1500-2000m (4920-6560ft)
2000-2500m (6560-8200ft), 2500-3000m (8200-9840ft)
Press time key and select installaton altitude in 500m steps. Temperature
and timer display are blinking. Confirm altitude setting with core
temperature key.
Press time key and adjust displayed rpm with timer dial
SE12 = MIN rpm; SE13 = Start rpm; SE14 = MAX rpm
Always check CO
2
values in function test
Steam heating time since last SC-Automatic
Preset Steam heating time until SC-Automatic
(default 45min, 20-120 min adjustable)
Setting new gas type (G20, G25, G30, G31, 13A, (ref. SE9-17)
Presetting of
CO
2
screw
on gas valve after gas type modification.
Show mode (on - oFF)
Press time key and adjust preset steam heating time from 20 - 120 minutes
with timer dial
Flushing time SC-Automatik
(default 45 seconds)
Press time key and adjust flushing time of SC-automatik from 30 - 90
seconds with timer dial
Press time key and select "on" or "oFF" in with timer dial
Operation steam generator pump
(continous or pulsing mode)
Activate selected step with timer key
Press time and core key for 5 seconds to set steam heating time to preset
steam heating time plus 1 minute
Service Level: SE -- Basic settings
SE
Basic settings
Select desired step with timer dial
(fan motor and heating elements are automatically OFF)
I - 19
Содержание SelfCooking Center SCC
Страница 29: ...Notes I 29...
Страница 30: ...Notes I 30...
Страница 31: ...Notes SCC Control panel 1 2 3 4 II 01...
Страница 49: ...Running Times SCC 19 Number of occurrence Reset possible 4 RESET Emergency Conroller Running Times II 19...
Страница 61: ...Notes Drain Valve Control II 31 Direction 1 Direction 2...
Страница 68: ...Notes II 38...
Страница 84: ...Notes III 16...