1
2
3
4
5
6
7
8
9
Quenching (set to 70°C/158°F)
Thermocouple B2
B2 above set Temp.: Y2 active
B2 below set Temp.: Y2 not active
Y2 active: 230VAC, X19:(2-4)
Y2 not active: 0VAC, X19:(2-4)
Hot Air supply (8 sec off - 8 sec. on)
Cabinet sensor B1
SSR active: 12VDC X24:(7-8)+(3-4)
SSR not active: 0VDC X24:(7-8)+(3-4)
Decision of Hot Air supply by PCB
logic
Steam supply (8 sec on - 8 sec off)
Quenching sensor B2
SSR active: 12VDC X24:(1-2)+(5-6)
SSR not active: 0VDC X24:(1-2)+(5-6)
After reaching temperature steam
saturation is calculated by internal
logic via B1 and B2
Timer starts after successful preheating
Logic on PCB
Blinking dot in timer display
Preheat steam generator 85°C (185°F);
SSR are energized
Thermocouple B5 inside
Steam Generator
SSR active: 12VDC X24:(1-2)+(5-6)
SSR not active: 0VDC X24:(1-2)+(5-6)
Heating elements de-energize
when B5 above 180°C (356°F)
Check water level inside steam generator
Level electrode S2 inside
Steam Generator
X12:(1-4) > 2VAC => no water
X12:(1-4) ~ 0VAC => water
Mode: Finishing
Temp. range 30-300°C (86-572°F)
Function Step
Responsible sensor
Signal
Select Finishing
(
Recom. Temp
. 100-140°C (212-284°F))
Select time or core temperature
Close cabinet door
Reed switch S3
Door open: 12VDC X27:(1-2)
Door closed: 0VDC X27:(1-2)
Sequence of events: CM electric
Remark
Solenoid Y1 energizes when no
water, 230VAC, X19:(1-3)
NOTE: For initial heating of cabinet => alternately energy supply of Steam and Hot Air (8 seconds each)
I - 14
Содержание SelfCooking Center SCC
Страница 29: ...Notes I 29...
Страница 30: ...Notes I 30...
Страница 31: ...Notes SCC Control panel 1 2 3 4 II 01...
Страница 49: ...Running Times SCC 19 Number of occurrence Reset possible 4 RESET Emergency Conroller Running Times II 19...
Страница 61: ...Notes Drain Valve Control II 31 Direction 1 Direction 2...
Страница 68: ...Notes II 38...
Страница 84: ...Notes III 16...