Local ventilation
Observe the following instructions when installing an extractor hood:
n
VDI Guideline 2052, NFPA 96 and the guidelines of the local building com-
mission for extractor hoods.
n
The extractor hood must extend 300-500 mm [12 – 20 inch] beyond the
front of the unit.
n
When using a VarioSmoker, install the device under an externally ventilated
extractor hood.
n
Install a grease filter in the overhanging area of the extractor hood.
Extractor hood
An extractor hood (also for retrofitting) is available for the units. To install the
extractor hood, follow the installation instructions supplied with the extractor
hood.