47
7 Water connection
Important for treated water connections:
To increase filter capacity, split the water con-
nection like shown in chapter 7.2 into cold and
treated water inputs (not possible with size 60
units) - remove the common water supply line.
i
NOTICE
Unit size 60 is single water connection only.
All others are for split water connection.
Filter size sufficient for:
Average treated water consumption
(without hose shower) at max. flow rate of
4,3gal/min.
Average Treated Water Consumption:
Appliance size
60
61
62
11
12
21
22
[gal/h]
N/A
0,8
2,2
1,7
2,9
3,5
4,2
Important for filter connections:
Water hose with minimum interior ø 1/2”.
Filter connection ø 3/4”.
When using a combination of filters, ensure filter
sequence of A-B-C or A-B-D in direction of flow.