Wiring Emergency Phones to the SmartRescue
Step 6
Wiring the Emergency Phones to the SmartRescue
Wiring Emergency Phones to the SmartRescue
*Use 22 or 24 AWG 2-pair twisted, shielded cable between
the phones and the SmartRescue. The maximum communi-
cation run is 5,100’
Connecting wire run:
To SmartRescue:
Insert 4 wires for each phone as shown
on the SmartRescue Diagram
To Phone:
Wire out to a standard 2-pair RJ11 phone jack.
Connect this jack to the 5’ cord supplied by Rath.
Emergency Phone
SmartRescue
The Emergency Phones come with a 5’ cord with an RJ11
on both ends. If you received a spade connector, your
company requested it. Wire according to your company
guidelines.
*Shields from the cabling runs (if used) should be
attached to one of the mounting screws on the
SmartRescue housing.
Ye
llow (PIN-1)
Green (PIN-2)
Red (PIN-3)
Black (PIN-4)