Items Needed for Installation
Item
Description
Wall Mounting Hardware
If Mounting to Wall
Pole Mount Bracket (RP7700098A)
If Mounting to Pole
#1 Phillips Screwdriver
Voltage Meter
Security Torx Bit
Provided by RATH®
Adjustable Wrench
120v Power Source
Analog Phone Line
If Using Landline
Phone Cable
If Using Landline
Call Station Installation
1.
Remove 12 security screws from unit.
2.
Remove top cap from unit.
3.
Pull front assembly away from back unit.
4.
Disconnect the gray Wago connector (see diagram on page
11
).
5.
If wall mount, mount to wall.
6.
If pole mount, attach unit to pole using Pole Mounting Bracket (Part # RP7700098A).
7.
Connect the electrical conduit of the 110vac bolt supply to the Call Station and run necessary wires.
8.
Connect 110vac wiring to the Call Station power cable (see diagram on page 1
1
).
9.
Turn on 110vac power to the Call Station.
Once the electrical is “live”, the phone needs to be programmed and tested. Reconnect the Wago connectors that
attach the front plate to the NEMA 4 box. If the phone will be programmed remotely, secure the front assembly to the
back panel and reinstall the 12 screws to the sides of the unit. If the phone will be programmed on-site, proceed to
the directions for “On-Site Programming”.
Page 4
Battery Installation
1.
Install battery in bottom of Call Station.
2.
Connect the power cables to the battery (red to positive and black to negative) and secure with
nut/bolt/washer (provided).
Note:
Batteries that will not be installed within
90 days should be connected to a RATH® Charger
Part # RP7700100AV. Failure to do this may result
in the battery not working correctly upon installation
or shortening of the battery life.
Power Cable Connection
60 Ah Battery