Intended Use 

 

This Immersion Heater Circulator is intended for the purpose of heating water in a laboratory water bath or inside other containers 
designed for the purpose. The operator may load a suitable article into the water bath for the purpose of controlled temperature 
application. The Immersion Heater Circulator is intended for use with tap water or filtered water only, as well as suitable additives 
where required as outlined in this User Manual. 
 
The Immersion Heater Circulator is 

not

 intended for use with any medium other than those outlined in this User Manual. The Immersion 

Heater Circulator is 

not

 intended to provide direct contact between the medium (water) and an unprotected medical, food, biological or 

medico-techno item. In all cases the item should be enclosed in a suitable vessel as described below to protect it from coming into 
contact with the Immersion Heater Circulator. 
 

Suitable Articles For Use With This Immersion Heater Circulator 

 

 

Plastic or glass laboratory test tubes that are sealed, waterproof and rated to withstand the intended temperature. 

 

Plastic or stainless steel laboratory test tube racks that are rated to withstand the intended temperature. 

 

An example of a suitable article would be a sealed plastic laboratory centrifuge tube filled with blood. 

 

Unsuitable Articles For Use With This Immersion Heater Circulator 

 

Any item where the article is not waterproof or may result in its contents coming into contact with the Immersion Heater 
Circulator or the heating medium (water). 

 

Any item that is not rated to withstand the intended temperature. 

 

An example of an unsuitable article would be an exposed piece of animal or plant matter. 

 

Suitable Environments For The Immersion Heater Circulator 

 

The Immersion Heater Circulator is intended for use in a clean laboratory environment only where adequate ventilation, a good 
power supply and provisions for routine cleaning are available. The Immersion Heater Circulator should not be used outdoors or 
in dirty, dusty, steamy, humid or windy environments. The acceptable operating conditions are outlined further in this User 
Manual.

  

 

General Operation 

 

The Immersion Heater Circulator is mounted onto a suitable laboratory water bath or other rigid water container using 
the adjustable mounting clamp, retort mounting boss or water bath bridge plate. 

 

The water bath or vessel is filled with water following the safety guidelines contained within this User Manual. 

 

The Immersion Heater Circulator is plugged into an appropriate power source. It is powered by an alternating current 
power supply with protective earth and with the appropriate receptacle, rated voltage and frequency for the country of 
its intended use. Further details on power requirements are outlined in this User Manual. 

 

A suitable article (as defined above) is placed inside the water bath or vessel. 

 

The Immersion Heater Circulator is operated via a combination of front and rear panel buttons and switches consisting of 
a power switch, temperature control buttons and menu buttons. These controls allow the operator to set a required 
water temperature as well as over and under temperature alarm set points.. 

 

The Immersion Heater Circulator should be operated strictly in accordance with the Operating Instructions outlined 
further in this User Manual. 

 

Operator Responsibility – Safety Considerations 

 

When operated in strict accordance with this User Manual, plus routine cleaning and maintenance being carried out, the product shall 
provide safe operation for the operator. The operator should be aware of the following before installing and operating the product :

 

 
Conditions of Operation 
 
*Note:

 The term “operator” referred to in this User Manual  is the primary person who has been tasked to install, maintain 

and train in the usage of this equipment. Other personnel shall be referred to as “Users”. 

 

Содержание TH8000

Страница 1: ...nglish www ratek com au www ratek com au www ratek com au www ratek com au 60 Wadhurst Dve Boronia Victoria 3155 Australia P 613 9887 2161 F 613 9887 2163 E sales ratek com au All Rights Reserved Made...

Страница 2: ...pect the condition of the product to ensure it has not been damaged in transit Any damage should be reported immediately to the responsible carrier If the product is damaged in any way re pack the pro...

Страница 3: ...stallation 10 Unpacking and Installing 10 Filling The Water Bath 11 Adjusting the Mounting Clamp 11 Adjusting the Pump Flow Rate 11 Attaching a Hose For External Pump Out 11 Connecting Power 11 Switch...

Страница 4: ...for use in a clean laboratory environment only where adequate ventilation a good power supply and provisions for routine cleaning are available The Immersion Heater Circulator should not be used outdo...

Страница 5: ...the equipment before using the product Plug the equipment directly into a wall power outlet Do not plug the equipment into a multi socket adapter of any kind The equipment is intended for operation i...

Страница 6: ...nces Colours Black on a yellow background The Immersion Heater Circulator is fitted with a removable guard which protects against contact with the heating element This guard MUST REMAIN FITTED at all...

Страница 7: ...following operating procedures before installing or operating the Immersion Heater Circulator in order to achieve the best performance and maximum attainable user safety Identification of Controls Fu...

Страница 8: ...boil water Safety Warnings Throughout this User Manual specific warnings will be supplied which relate to the current operation being referred to These warnings are supplied in addition to the main wa...

Страница 9: ...e serious injury or danger to life CAUTION Always work above the level of the Immersion Heater Circulator to avoid spillage of dangerously hot water At no point should the user operator animal or any...

Страница 10: ...bath to allow for adequate ventilation and for steam to dissipate Ensure that there is a suitable mains power supply outlet within reach of the supplied mains power lead without placing any strain wh...

Страница 11: ...your Immersion Heater Circulator before filling the water bath if you are unsure of your water supply CAUTION Before filling the water bath ensure the mains power supply outlet is switched off and tha...

Страница 12: ...epth as required Once the depth has been set re tighten the 2 clamp screws by gently tightening in a clockwise direction Step 2 Once the unit is placed on the bath gently tighten the thumb screw by tu...

Страница 13: ...er diameter no larger than 15mm Silicon hose is recommended for most applications Simply push the hose over either outlet until it touches the guard a hose clamp may be used if required however this i...

Страница 14: ...ins power supply outlet Switching On The Immersion Heater Circulator CAUTION Ensure you have filled the water bath to at least the minimum required level before switching on power Failure to do so may...

Страница 15: ...hese high temperatures particularly whilst loading and unloading containers racks or accessories ALWAYS use appropriate tools such as silicon insulated tongs to lower such containers into the water to...

Страница 16: ...en operating in SP2 Preset Mode and the current temperature may cause the alarms to activate if the bath temperature is outside the acceptable alarm range Setting the Over and Under Temperature Alarms...

Страница 17: ...iners suitable for the water temperature selected When loading use appropriate tools such as silicon insulated tongs to slowly place the required rack container or accessory into the bath Ensure the i...

Страница 18: ...ing CAUTION Be careful when lifting and observe your local operational health and safety requirements for lifting before relocating the Immersion Heater Circulator Ask for help if you are unable to mo...

Страница 19: ...nents or water seals Ratek are consulted prior to decontamination or cleaning being undertaken if there is any doubt about the compatibility of decontamination or cleaning agents with parts of the Imm...

Страница 20: ...to an authorized service technician for repair Over Temperature Safety Cutout Test The over temperature safety cutout should be tested periodically to ensure correct operation This test should be cond...

Страница 21: ...Circulator unattended during the test Once the top coil of the heating element has become exposed the over temperature cutout should have activated When the cutout activates a small click sound may be...

Страница 22: ...fuse holder requires technician to replace F250V 10AL F250V 5AL Heating Power 2 200 Watts 1 000 Watts Total Operating Wattage 2 220 Watts 1 020 Watts Minimum Tank Depth 200mm Minimum Water Level 120mm...

Страница 23: ...al this may indicate a fault condition If the Immersion Heater Circulator fails to operate this may also indicate a fault condition Fault conditions must be referred to an authorized service technicia...

Страница 24: ...he product including but not limited to biological samples tubes racks accessories flasks containers or the contents of such containers caused by the malfunction of the product or the failure of the p...

Страница 25: ...g is not available the unit must be packed with extreme care to ensure a safe journey Fragile and This Way Up labels should be applied to the carton in a prominent location No liability for a unit dam...

Отзывы: