The operator shall be aware that the protection provided by the equipment may be impaired if the equipment is used with 
accessories not provided or recommended by the manufacturer, is modified in any way or is used in a manner not 
specified by the manufacturer.

 

 

The operator is responsible for ensuring all users of the product are qualified to do so, and are well versed in common 
safety concepts. The product should only be operated by an adult who has read and understood this User Manual 
provided in the appropriate language in its entirety.

  

 

Any user must be informed by the responsible operator of any potential hazards that may arise through the use of this 
equipment in the course of their work, including any local environmental hazards not related directly to the Immersion 
Heater Circulator. They should also be able to demonstrate that they understand any preventative safety measures in 
operation prior to operating the equipment. 

 

The operator shall agree to accept responsibility for the use of the equipment in accordance with this User Manual, and 
be fully aware that the equipment is designed for commercial use.  

 

It is assumed that the user and operator have had experience in a commercial environment, and had appropriate training 
in how to perform their work safely in accordance with any local operational health and safety regulations. The operator 
and all users should be well versed in local emergency procedures as per the workplace safety regulations in effect. 

 

Avoid any direct impact with any surface of the equipment, including the casing, cover panel, element, pump or control 
panel. 

 

Important: 

Do not use any sharp or pointed metal objects anywhere near the equipment, in particular the control panel. 

 

Avoid using the equipment near any other vibrating equipment or source of excessive vibration. 

 

Ensure the equipment is cleaned and maintained in accordance with this User Manual. 

 

Ensure that all original safety warning labels are in an adequate, legible condition and are firmly affixed to the equipment 
before using the product. 

 

Plug the equipment directly into a wall power outlet. Do not plug the equipment into a multi-socket adapter of any kind. 

 

The equipment is intended for operation in a controlled electromagnetic environment. Avoid the use of transmitting 
devices (e.g. cellular or mobile telephones) near the equipment whilst operating. A minimum distance of 2 Metres from 
the product is recommended for any transmitting device. 

 

Important: 

The equipment must only be installed and operated in 

well ventilated areas

. The unit is not intended for use 

in explosive atmospheres, in confined spaces or inside any other piece of laboratory equipment such as humidity cabinets 
or incubators. 

 

The allowed operating environment must be between 5° Celsius and 40° Celsius ambient air temperature. Be aware that 
the ambient air temperature will limit the minimum controllable water temperature. The ambient air temperature must be 
at least 7° Celsius lower than the desired controllable water temperature. 

 

The maximum allowed relative humidity of the operating environment is 80%. 

 

The equipment should not be stored in direct sunlight, near chemicals, or other contaminants. 

 

If any of these safety recommendations cannot be achieved or the equipment has been damaged in any way, the 
equipment should not be installed or operated. 

 

Important : 

If you have any concerns or questions relating to operator or user safety, please contact the appropriate 

Ratek Customer Service department before installing and operating the unit. Contact details are provided in this User 
Manual. 

 

Safety Labels And Markings 

 
The equipment is provided with safety caution labels. An explanation of each caution label is provided below. It is the 
responsibility of the operator and user to fully understand the meaning of these warning labels prior to operating the 
equipment. 
 

Very Important: Particular care should be taken when working near the heating element at the bottom of the Immersion 

Heater Circulator. At all times during operation the supplied safety guard MUST REMAIN FITTED to the Immersion Heater 

Circulator to avoid possible burns or scalds from the heating element. 

  

The operator or user must also take extreme care when the bath is working at temperatures above 50° C as steam will be 

present and can cause scalding. 

Содержание TH8000

Страница 1: ...nglish www ratek com au www ratek com au www ratek com au www ratek com au 60 Wadhurst Dve Boronia Victoria 3155 Australia P 613 9887 2161 F 613 9887 2163 E sales ratek com au All Rights Reserved Made...

Страница 2: ...pect the condition of the product to ensure it has not been damaged in transit Any damage should be reported immediately to the responsible carrier If the product is damaged in any way re pack the pro...

Страница 3: ...stallation 10 Unpacking and Installing 10 Filling The Water Bath 11 Adjusting the Mounting Clamp 11 Adjusting the Pump Flow Rate 11 Attaching a Hose For External Pump Out 11 Connecting Power 11 Switch...

Страница 4: ...for use in a clean laboratory environment only where adequate ventilation a good power supply and provisions for routine cleaning are available The Immersion Heater Circulator should not be used outdo...

Страница 5: ...the equipment before using the product Plug the equipment directly into a wall power outlet Do not plug the equipment into a multi socket adapter of any kind The equipment is intended for operation i...

Страница 6: ...nces Colours Black on a yellow background The Immersion Heater Circulator is fitted with a removable guard which protects against contact with the heating element This guard MUST REMAIN FITTED at all...

Страница 7: ...following operating procedures before installing or operating the Immersion Heater Circulator in order to achieve the best performance and maximum attainable user safety Identification of Controls Fu...

Страница 8: ...boil water Safety Warnings Throughout this User Manual specific warnings will be supplied which relate to the current operation being referred to These warnings are supplied in addition to the main wa...

Страница 9: ...e serious injury or danger to life CAUTION Always work above the level of the Immersion Heater Circulator to avoid spillage of dangerously hot water At no point should the user operator animal or any...

Страница 10: ...bath to allow for adequate ventilation and for steam to dissipate Ensure that there is a suitable mains power supply outlet within reach of the supplied mains power lead without placing any strain wh...

Страница 11: ...your Immersion Heater Circulator before filling the water bath if you are unsure of your water supply CAUTION Before filling the water bath ensure the mains power supply outlet is switched off and tha...

Страница 12: ...epth as required Once the depth has been set re tighten the 2 clamp screws by gently tightening in a clockwise direction Step 2 Once the unit is placed on the bath gently tighten the thumb screw by tu...

Страница 13: ...er diameter no larger than 15mm Silicon hose is recommended for most applications Simply push the hose over either outlet until it touches the guard a hose clamp may be used if required however this i...

Страница 14: ...ins power supply outlet Switching On The Immersion Heater Circulator CAUTION Ensure you have filled the water bath to at least the minimum required level before switching on power Failure to do so may...

Страница 15: ...hese high temperatures particularly whilst loading and unloading containers racks or accessories ALWAYS use appropriate tools such as silicon insulated tongs to lower such containers into the water to...

Страница 16: ...en operating in SP2 Preset Mode and the current temperature may cause the alarms to activate if the bath temperature is outside the acceptable alarm range Setting the Over and Under Temperature Alarms...

Страница 17: ...iners suitable for the water temperature selected When loading use appropriate tools such as silicon insulated tongs to slowly place the required rack container or accessory into the bath Ensure the i...

Страница 18: ...ing CAUTION Be careful when lifting and observe your local operational health and safety requirements for lifting before relocating the Immersion Heater Circulator Ask for help if you are unable to mo...

Страница 19: ...nents or water seals Ratek are consulted prior to decontamination or cleaning being undertaken if there is any doubt about the compatibility of decontamination or cleaning agents with parts of the Imm...

Страница 20: ...to an authorized service technician for repair Over Temperature Safety Cutout Test The over temperature safety cutout should be tested periodically to ensure correct operation This test should be cond...

Страница 21: ...Circulator unattended during the test Once the top coil of the heating element has become exposed the over temperature cutout should have activated When the cutout activates a small click sound may be...

Страница 22: ...fuse holder requires technician to replace F250V 10AL F250V 5AL Heating Power 2 200 Watts 1 000 Watts Total Operating Wattage 2 220 Watts 1 020 Watts Minimum Tank Depth 200mm Minimum Water Level 120mm...

Страница 23: ...al this may indicate a fault condition If the Immersion Heater Circulator fails to operate this may also indicate a fault condition Fault conditions must be referred to an authorized service technicia...

Страница 24: ...he product including but not limited to biological samples tubes racks accessories flasks containers or the contents of such containers caused by the malfunction of the product or the failure of the p...

Страница 25: ...g is not available the unit must be packed with extreme care to ensure a safe journey Fragile and This Way Up labels should be applied to the carton in a prominent location No liability for a unit dam...

Отзывы: