Ratek TH8000 Скачать руководство пользователя страница 11

Ratek TH8000/TH8200 Precision Immersion Heater Circulator - User Manual 

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 

Page 11 of 25

 

 

ALWAYS

 be 100% sure of the contents of your containers, the expected behavior once heated and the applicable 

safety measures that should be employed when handling such substances. 
 

ALWAYS

 ensure your containers are firmly sealed and there is no chance of the sample leaking into the water bath . 

 

ALWAYS

 use plastic, stainless-steel or plastic powder-coated tubes racks and accessories in the water bath . This 

will assist to prevent corrosion and thus help to extend the useful life of the Immersion Heater Circulator. 
 

   

 

 

 

CAUTION 

Poor water quality can lead to corrosion of the Immersion Heater Circulator even though it is constructed from high 
quality stainless steel, and eventually lead to a potentially hazardous situation. The Immersion Heater Circulator is 
intended for use with tap water or filtered water only. 

 

 
Depending on local conditions, the water supply may be ferrous or overly chlorinated. Both of these conditions may 
lead to corrosion if used with the Immersion Heater Circulator. 
 
Distilled or de-ionized water may lead to corrosion if used with the Immersion Heater Circulator. 
 
Use of any liquid medium other than that recommended above will void the product warranty. 
 
Contact the supplier of your Immersion Heater Circulator before filling the water bath if you are unsure of your 
water supply. 

 

 

 

 

CAUTION 

Before filling the water bath, ensure the mains power supply outlet is switched 

off

 and that the mains lead to the 

Immersion Heater Circulator is 

unplugged

 from the mains power supply outlet.

 

 

The nature of pouring water is unpredictable and should be done carefully away from any electrical supply to avoid 
the risk of electric shock.  
 

 

 

 
 

Filling The Water

 

Bath

 

 

 

CAUTION

 

Always fill the water bath in a safe manner following the manufacturer’s guidelines where possible. It is important 
that power to the Immersion Heater Circulator is switched off at the mains outlet before filling the water bath to 
avoid possible electric shock.

 

 

 

 

 

CAUTION 

Do not over-fill the water bath. If the bath is over-filled, water may spill out and create a hazardous situation if it 
comes near an electrical current. 
 
The minimum water depth is 120 millimetres below the bath rim.  
 
The maximum water depth is 20 millimetres below the bath rim. 
 
If the water level falls below this minimum level during operation, the Immersion Heater Circulator will cut power to 
the heating element and the alarm will sound. If this occurs, the unit should be powered off, disconnected from the 
mains electrical supply and the water level topped up with cold water. Be aware that this may result in the rapid 
decrease in the water temperature and the effect of this in relation to the current procedure being carried out must 

Содержание TH8000

Страница 1: ...nglish www ratek com au www ratek com au www ratek com au www ratek com au 60 Wadhurst Dve Boronia Victoria 3155 Australia P 613 9887 2161 F 613 9887 2163 E sales ratek com au All Rights Reserved Made...

Страница 2: ...pect the condition of the product to ensure it has not been damaged in transit Any damage should be reported immediately to the responsible carrier If the product is damaged in any way re pack the pro...

Страница 3: ...stallation 10 Unpacking and Installing 10 Filling The Water Bath 11 Adjusting the Mounting Clamp 11 Adjusting the Pump Flow Rate 11 Attaching a Hose For External Pump Out 11 Connecting Power 11 Switch...

Страница 4: ...for use in a clean laboratory environment only where adequate ventilation a good power supply and provisions for routine cleaning are available The Immersion Heater Circulator should not be used outdo...

Страница 5: ...the equipment before using the product Plug the equipment directly into a wall power outlet Do not plug the equipment into a multi socket adapter of any kind The equipment is intended for operation i...

Страница 6: ...nces Colours Black on a yellow background The Immersion Heater Circulator is fitted with a removable guard which protects against contact with the heating element This guard MUST REMAIN FITTED at all...

Страница 7: ...following operating procedures before installing or operating the Immersion Heater Circulator in order to achieve the best performance and maximum attainable user safety Identification of Controls Fu...

Страница 8: ...boil water Safety Warnings Throughout this User Manual specific warnings will be supplied which relate to the current operation being referred to These warnings are supplied in addition to the main wa...

Страница 9: ...e serious injury or danger to life CAUTION Always work above the level of the Immersion Heater Circulator to avoid spillage of dangerously hot water At no point should the user operator animal or any...

Страница 10: ...bath to allow for adequate ventilation and for steam to dissipate Ensure that there is a suitable mains power supply outlet within reach of the supplied mains power lead without placing any strain wh...

Страница 11: ...your Immersion Heater Circulator before filling the water bath if you are unsure of your water supply CAUTION Before filling the water bath ensure the mains power supply outlet is switched off and tha...

Страница 12: ...epth as required Once the depth has been set re tighten the 2 clamp screws by gently tightening in a clockwise direction Step 2 Once the unit is placed on the bath gently tighten the thumb screw by tu...

Страница 13: ...er diameter no larger than 15mm Silicon hose is recommended for most applications Simply push the hose over either outlet until it touches the guard a hose clamp may be used if required however this i...

Страница 14: ...ins power supply outlet Switching On The Immersion Heater Circulator CAUTION Ensure you have filled the water bath to at least the minimum required level before switching on power Failure to do so may...

Страница 15: ...hese high temperatures particularly whilst loading and unloading containers racks or accessories ALWAYS use appropriate tools such as silicon insulated tongs to lower such containers into the water to...

Страница 16: ...en operating in SP2 Preset Mode and the current temperature may cause the alarms to activate if the bath temperature is outside the acceptable alarm range Setting the Over and Under Temperature Alarms...

Страница 17: ...iners suitable for the water temperature selected When loading use appropriate tools such as silicon insulated tongs to slowly place the required rack container or accessory into the bath Ensure the i...

Страница 18: ...ing CAUTION Be careful when lifting and observe your local operational health and safety requirements for lifting before relocating the Immersion Heater Circulator Ask for help if you are unable to mo...

Страница 19: ...nents or water seals Ratek are consulted prior to decontamination or cleaning being undertaken if there is any doubt about the compatibility of decontamination or cleaning agents with parts of the Imm...

Страница 20: ...to an authorized service technician for repair Over Temperature Safety Cutout Test The over temperature safety cutout should be tested periodically to ensure correct operation This test should be cond...

Страница 21: ...Circulator unattended during the test Once the top coil of the heating element has become exposed the over temperature cutout should have activated When the cutout activates a small click sound may be...

Страница 22: ...fuse holder requires technician to replace F250V 10AL F250V 5AL Heating Power 2 200 Watts 1 000 Watts Total Operating Wattage 2 220 Watts 1 020 Watts Minimum Tank Depth 200mm Minimum Water Level 120mm...

Страница 23: ...al this may indicate a fault condition If the Immersion Heater Circulator fails to operate this may also indicate a fault condition Fault conditions must be referred to an authorized service technicia...

Страница 24: ...he product including but not limited to biological samples tubes racks accessories flasks containers or the contents of such containers caused by the malfunction of the product or the failure of the p...

Страница 25: ...g is not available the unit must be packed with extreme care to ensure a safe journey Fragile and This Way Up labels should be applied to the carton in a prominent location No liability for a unit dam...

Отзывы: