background image

15

Draining

 

To drain off water from the inner tank:

1

st

 - Turn off both power and water supply. Let hot water inside the inner tank cool down if need.

2

nd

 - Unscrew the drain plug to release water.

 

Source of Water Supply

Never connect Rasonic’ s water heater to other source of water supply, other than the potable 

water supply as the result will have no warranty to the Company.

Water Shortage

During water shortage, do not drain water from inner tank. The heating element would be 

damaged if it is not submerged under water. When water supply resumes, turn on hot water tap 

and let water flows through the shower head before switching on the power.

內膽排水

 

如要將內膽內的水排走:

首先,必須先關掉電源及水源,等待剩餘之熱水冷卻 。

然後,旋開排水喉之喉蓋,讓水排出。  

水質問題 

切勿將熱水器連接到除飲用水供應以外的其他供水源,否則公司將不提供任何保用 。

停水期間

 

停水時不應將熱水器內之存水用盡,否則會導致發熱線損壞。恢復供水後,應先扭開熱水掣直至有

水從花灑流出。待內膽注滿水後,用戶才可重新開啟電源。

     OPERATING INSTRUCTIONS

     使用説明

Содержание RWH-CT5

Страница 1: ...7 Please read the operation instruction carefully before using and well keep it in a safe place for future reference Some figures in this instruction may not match with the real object just for refere...

Страница 2: ......

Страница 3: ...ct Information 8 4 Product Structure 8 5 Installation Instructions 9 6 Pre Installation Notice 10 11 7 Installation Diagram 12 8 Wiring Diagram 12 9 Technical Specification 13 14 10 Operating Instruct...

Страница 4: ...breaker MCB ii earth leakage circuit breaker ELCB It is normal if water drips from the Temperature and Pressure Relief Valve P T Valve while the water is being heated The maintenance access panel of...

Страница 5: ...5 i MCB ii ELCB...

Страница 6: ...Technical Principal ISM Hot Water Injection System Rasonic s Water Heater apply a 3rd Generation patented Hot Water Injection System including Combustion Chamber with rapid burner 3kW rating operated...

Страница 7: ...7 1 1 2 3 4 5 6 7 1 1 M6 6 4 1 1 1 1 ISM 3 PID PID 2 C...

Страница 8: ...8 Measurements PRODUCT INFORMATION Model No RWH CT5 RWH CT7 RWH CT5 RWH CT7 Height 690mm 690mm 690 690 Depth 168mm 195mm 168 195 Width 380mm 380mm 380 380 PRODUCT STRUCTURE...

Страница 9: ...hould not exceed 99 C and working pressure at 1 0MPa 10 bar Tighten and connect a drain pipe not supplied by manufacturer to the pressure and temperature relief valve Water might drip from the P T Val...

Страница 10: ...afety 3 The diameter of piping should be 1 2 BSP Connect the inlet pipe blue with water supply Then connect the outlet pipes red with supply pipe leading to points of use 4 Turn on the hot water tap T...

Страница 11: ...11 P T Valve 99 1 0MPa 10bar P T Valve 220 P T Valve 3 P T Valve 1 P T Valve P T Valve 2 P T Valve P T Valve 100 150 3 4...

Страница 12: ...12 WIRING DIAGRAM INSTALLATION DIAGRAM 690mm 380mm 34mm 70mm 180mm 100mm 195mm Hot water outlet Water inlet G1 2 G1 2 Hanger P T Valve 60mm 190mm Cable entrance...

Страница 13: ...6MPa 6Bar Maximum Pressure 220V 50Hz 3kW Rated Voltage Rated Loading 13 4 Ampere Rated Current G 1 2 Male BSP British Standard Pipe Thread Pipe Connection 75 80dg C Working Temperature Inner Tank IPX...

Страница 14: ...14 RWH CT5 RWH CT7 SUS304 20 13 33 24 15 39 1 0 MPa 10Bar 0 6MPa 6Bar 220 50 3 13 4 A 1 2 75 80 IPX4 CFC...

Страница 15: ...sonic s water heater to other source of water supply other than the potable water supply as the result will have no warranty to the Company Water Shortage During water shortage do not drain water from...

Страница 16: ...nnection call customer service department to check thermal cutout main controller or heating element if fuse and electrical connection is normal Check if the water temperature setting is appropriate o...

Страница 17: ...e must be vented slightly at regular intervals once per month to ensure proper functioning Pull the lever until the valve opens and water drains from the outlet Re close the valve If water continues t...

Страница 18: ...9867 6452 Special Avowal 1 If information above has been checked our company reserves the hermeneutic power to any print errors or misunderstanding on the content 2 In case there is any inconsistency...

Страница 19: ......

Страница 20: ......

Отзывы: