Positioning

Water heater should position near water tap of use in order to minimize heat loss and defects.

For wall-mount installation, appropriate anchor screws must be used, and wall should be strong 

enough to withstand the weight of water heater. Installation position should keep a minimal 

distant between the wall and water heater. 

Connecting P&T Valve and Inlet/Outlet Pipes

 

The Temperature & Pressure Relief Valve ( P&T Valve) has applied in water heater, when 

the temperature/ pressure in water heater is detected to be more than setting (99°C 

/1.0MPa (10bar)),water will be released through the P&T Valve to decrease pressure and 

temperature.

P&T Valve and Inlet/Outlet Pipes must be installed according to the following instructions:

 

1. Please refer to the P&T Valve installation label indicated on the water heater, P&T Valve must

    be installed on the accurate position according to the installation label.

2. When connecting the pipe of P&T Valve , the P&T Valve must be installed downward. 

    The outlet of the discharge pipe connecting the P&T Valve must be positioned approximately 

    100~150mm away from the ground, so that it is easily observable when hot water is being

    drained to ensure user safety. 

3. The diameter of piping should be 1/2” BSP.  Connect the inlet pipe (blue) with water supply.

Then connect the outlet pipes (red) with supply pipe leading to points of use. 

4. Turn on the hot water tap. Turn on water supply switch until the inner tank has been filled up

with water. The inner tank has been filled up when water flows from the water tap.

Power Switch

 

The external switch is used to completely disconnect water heater from power supply. It should 

disconnect all poles, and a contactor separation of at least 3mm must be present.

Initial Operation

Rasonic’s water heater hybrid series is designed for operation on 220VAC, and must be installed 

by authorizes technician with earthed outlet.
Fill the inner tank with water before conducting the following procedures:
• Ensure that the appliance is disconnected and that the fuse is deactivated.
• Turn on the hot water tap of the installed mixer to fill the appliance until

  bubble-free water emerges from the outlet.
• Check the system for leaks and remedy these if necessary.
• Switch on the appliance.
• The inner tank water temperature will automatic setting and remain in

  attendance while the water

 

Important:

Pre - Installation Notice

Installation and inspection should be processed by a licensed technician using the

supplied parts. Sole Distributor is not responsible for any defect or damage caused by

incorrect or unauthorized installation.

!

Содержание RWH-CT5

Страница 1: ...7 Please read the operation instruction carefully before using and well keep it in a safe place for future reference Some figures in this instruction may not match with the real object just for refere...

Страница 2: ......

Страница 3: ...ct Information 8 4 Product Structure 8 5 Installation Instructions 9 6 Pre Installation Notice 10 11 7 Installation Diagram 12 8 Wiring Diagram 12 9 Technical Specification 13 14 10 Operating Instruct...

Страница 4: ...breaker MCB ii earth leakage circuit breaker ELCB It is normal if water drips from the Temperature and Pressure Relief Valve P T Valve while the water is being heated The maintenance access panel of...

Страница 5: ...5 i MCB ii ELCB...

Страница 6: ...Technical Principal ISM Hot Water Injection System Rasonic s Water Heater apply a 3rd Generation patented Hot Water Injection System including Combustion Chamber with rapid burner 3kW rating operated...

Страница 7: ...7 1 1 2 3 4 5 6 7 1 1 M6 6 4 1 1 1 1 ISM 3 PID PID 2 C...

Страница 8: ...8 Measurements PRODUCT INFORMATION Model No RWH CT5 RWH CT7 RWH CT5 RWH CT7 Height 690mm 690mm 690 690 Depth 168mm 195mm 168 195 Width 380mm 380mm 380 380 PRODUCT STRUCTURE...

Страница 9: ...hould not exceed 99 C and working pressure at 1 0MPa 10 bar Tighten and connect a drain pipe not supplied by manufacturer to the pressure and temperature relief valve Water might drip from the P T Val...

Страница 10: ...afety 3 The diameter of piping should be 1 2 BSP Connect the inlet pipe blue with water supply Then connect the outlet pipes red with supply pipe leading to points of use 4 Turn on the hot water tap T...

Страница 11: ...11 P T Valve 99 1 0MPa 10bar P T Valve 220 P T Valve 3 P T Valve 1 P T Valve P T Valve 2 P T Valve P T Valve 100 150 3 4...

Страница 12: ...12 WIRING DIAGRAM INSTALLATION DIAGRAM 690mm 380mm 34mm 70mm 180mm 100mm 195mm Hot water outlet Water inlet G1 2 G1 2 Hanger P T Valve 60mm 190mm Cable entrance...

Страница 13: ...6MPa 6Bar Maximum Pressure 220V 50Hz 3kW Rated Voltage Rated Loading 13 4 Ampere Rated Current G 1 2 Male BSP British Standard Pipe Thread Pipe Connection 75 80dg C Working Temperature Inner Tank IPX...

Страница 14: ...14 RWH CT5 RWH CT7 SUS304 20 13 33 24 15 39 1 0 MPa 10Bar 0 6MPa 6Bar 220 50 3 13 4 A 1 2 75 80 IPX4 CFC...

Страница 15: ...sonic s water heater to other source of water supply other than the potable water supply as the result will have no warranty to the Company Water Shortage During water shortage do not drain water from...

Страница 16: ...nnection call customer service department to check thermal cutout main controller or heating element if fuse and electrical connection is normal Check if the water temperature setting is appropriate o...

Страница 17: ...e must be vented slightly at regular intervals once per month to ensure proper functioning Pull the lever until the valve opens and water drains from the outlet Re close the valve If water continues t...

Страница 18: ...9867 6452 Special Avowal 1 If information above has been checked our company reserves the hermeneutic power to any print errors or misunderstanding on the content 2 In case there is any inconsistency...

Страница 19: ......

Страница 20: ......

Отзывы: