Rasmussen RF-RF-LD30/36-VEI-N/P Скачать руководство пользователя страница 4

4

 

 

24 

PARTS LIST (Cont’d) 

 

23 

26 

22.    GV60 Electronic Ignition Gas Valve (

GV60-VNG

(Natural gas) (

GV60-VLP

(Propane) 

27.   nterruptor Receiver Cable (

GV60-RCA)

 

 

23.     Remote / Transmitter, Variable Height Control (

GV60-TXB)                                             

28.    On / Off Switch Cable (

GV60-SWA)   

 

 

24.    Module / Receiver(

GV60-RXA)

  

 

 

 

 

 

29.      8 Wire Cable (

GV60-C8)

 

 

25.    Interrupter Block(

GV60-TIA) 

 

 

 

 

 

30.    GV60 Battery Box / Cable (

GV60-BCA)

   

 

26.  Ignition Cable (

GV60-ICA)  

 

 

 

 

                  31.     

Plug in Adapter for AC Power Supply 

(GV60-AC)

 

 

32.   RF-LD

30/36, 42/48, 60/72 Valve Vanisher                                                                 

33.    Hard wire wall switch (

GV60-SW1

)                                             

 

 

 

 

 

 

                                                                                                                                                                                                                                                

22 

28 

32 

27 

25 

29 

30 

Wall Switch 

Harness 

2 Screws 

Optional Accessory: (Not included) 

33 

31 

Optional Accessory: Not Included

 

Содержание RF-RF-LD30/36-VEI-N/P

Страница 1: ...ed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with type of gas indicated on the rating plate INSTALLER Leave this...

Страница 2: ...epair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to exc...

Страница 3: ...LD30 36 2 Rating I D Plate 3 Flex Connector SSCB 14 4 3 8 x 1 2 FIP Flared Brass Fitting A1 5 Orifice Spud see page 12 for size 6 Orifice Holder Internally Tapped 3 8 x 3 8 Flared MIP Fitting A2T 7 A...

Страница 4: ...Switch Cable GV60 SWA 24 Module Receiver GV60 RXA 29 8 Wire Cable GV60 C8 25 Interrupter Block GV60 TIA 30 GV60 Battery Box Cable GV60 BCA 26 Ignition Cable GV60 ICA 31 Plug in Adapter for AC Power Su...

Страница 5: ...and ventilation air must conform with The National Fuel Gas Code ANSI Z223 1 NFPA54 or The CSA B149 1 Natural Gas and Propane Installation Code latest edition STEP ONE PREPARATION 1 Verify that the Va...

Страница 6: ...E REQUIREMENTS The minimum permanent free opening of the fireplace chimney or chimney damper must be at least the minimum Chimney Area shown below based on a minimum chimney height of at least 8 feet...

Страница 7: ...propane gas burner A Natural Gas B Propane FIGURE 6 STEP TWO Sprinkle a light covering of Ember Magic over the Pan Medium Figure 6A and Figure 6B Pull apart Ember Magic fiber material to enhance the g...

Страница 8: ...charred burnt effect between the two halves Figure 8 and Figure 9 Place the Longest Log or 2 largest charred logs if applicable Figure 8A and 9A as far forward on the Grate as possible The remaining l...

Страница 9: ...ing BATTERY PACK PLACEMENT NOTE Any beeping or unexpected shutdown may be the over temperature safety feature in the receiver If this happens move the receiver into a cooler area and or use the RH2 RH...

Страница 10: ...ROL SETTINGS ON GAS VALVE WHILE OPERATING WITH REMOTE TRANSMITTER Valve switch set to 0 Valve switch set to I VALVE IN 0N POSITION Valve switch set to I Flame height control knob turned 0N Flame heigh...

Страница 11: ...beep release the reset button Within the subsequent 20 second press the small flame button on the handset until you hear two additional short beeps confirming the code is set If you hear one long bee...

Страница 12: ...k pilot flame Weak pilot flame is the NUMBER 1 SERVICE ISSUE REGARDING NUISANCE SHUT OFF Using canned compressed air blow out the opposing air intake ports located at the base of the pilot where the g...

Страница 13: ...l light properly The pilot flame should be steady and soft blue surrounding 1 8 inch of the thermocouple Pilot Tube Air Intake Port Thermocouple Tip Piezo Spark Blue Dot Natural Gas Red Dot Propane 1...

Страница 14: ...which have been closed or are obstructed with debris will not allow sufficient combustion air into the burner Use compressed air and or a soft bristle brush to clean the air mixer area Air mixers sho...

Страница 15: ...alve Vanisher Make sure the fireplace floor is even with the Hearth floor Also change batteries Odor and or Smoke After Break in Period other than Natural Odor of Gas Combustion Most likely causes Lac...

Страница 16: ...The maximum liability of RASMUSSEN in connection with this limited warranty shall not in any case exceed the contract price paid for the product claimed to be defective or unsuitable 4 This warranty...

Отзывы: