LIGHTING AND OPERATION WITH REMOTE / TRANSMITTER
KEEP BURNER AREA CLEAN AND PERFORM 3 AIR INTAKE PORTS
CLEANING ANNUALLY
LIGHTING INSTRUCTION FOR MANUAL CONTROL
1.
Stop!
Read the safety information included before proceeding.
2. Turn Flame Height Control knob to the
“OFF,”
full clockwise position.
3.
Turn MANUAL knob to the “
MAN,
” full clockwise position.
4.
Place ON/OFF switch in “
O
” (
OFF
position).
5.
Wait five (5) minutes for the gas to dissipate.
If you detect gas STOP! Check for with soap and water not with open flame.
6. Place ON/OFF switch in
I (ON
position) (See Valve Picture).
7. With the valve knob in
MAN
position a manual pilot valve operator.
8. Fully push down on manual pilot valve operator and hold in, to start pilot gas flow.
9. Light pilot with a match or lighter.
10. Once pilot is lit, continue to depress pilot valve operator and hold until the pilot flame remains lit
(approximately 30 to 60 seconds).
Note: If pilot does not remain lit, depress and wait at least 5 minutes to allow gas to dissipate (Then
repeat 9 & 10).
11.
Turn valve knob to the “
ON
”, full counterclockwise.
12. Turn Flame control knob to the
FULL ON
, full counterclockwise position (5pm position)
(See pg. 2; Manual Operation)
13. To turn off burner and allow pilot to remain lit, turn valve knob clockwise to
“MAN”
position.
IMPORTANT SERVICE TIP!
Obstructed Pilot Air Intake Ports result in an improper gas/air mixture and a weak pilot flame.
Weak
pilot flame is the NUMBER 1 SERVICE ISSUE REGARDING NUISANCE SHUT-OFF.
Using canned compressed air, blow out the
opposing air intake ports located at the base of the pilot. (where the gas supply line attaches to the pilot)
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Large Flame
Button
Small flame
Button
Pilot Valve Operator
Thermocouple
Air Intake hole
(Clean Annually)
Pilot barrel
Pilot Assembly
Electrode
Blue Dot Natural gas; Red Dot Propane
Flame Height
Control Knob
Valve Switch
Valve Knob
FLAME HEIGHT ADJUSTMENT USING REMOTE / TRANSMITTER
(Picture of transmitter with manual mode display on screen)
•
In standby mode: Press and hold
(large flame) button to increase flame height
•
Press and hold
(small flame) button to decrease flame height or to keep the pilot lit.
•
When relighting the burner, press and hold the large flame button until flame height control knob
reaches 5pm position.
•
For fine adjustment tap
(large flame) of
(small flame) buttons.
(1 Picture of each transmitter with Low and On display on screen)
•
Double-click
(small flame) button. “LO” will be displayed.
NOTE:
Flame automatically goes to designated low fire.
•
Double-click
(large flame) button. “HI” will be displayed.
NOTE:
Flame automatically goes to designated high fire.
Designated Low and High Fire
Note: When turning flame control knob, do not force. Knob has a slip clutch that clicks until the end stops are reached. This allows for
manual flame height adjustment as well as adjustment to pilot standby position.
IMPORTANT!
IMPORTANT!
Note:
If the pilot flame shuts off, press the off button on the remote / transmitter and wait 5 minutes before relighting.