CARBON MONOXIDE POISONING MAY LEAD TO DEATH 

 

 When used without fresh air, decorative gas appliances may give off carbon monoxide, an odorless, colorless,  

poisonous  gas. Some people, pregnant women, persons with heart or lung disease, anemia, persons under the  

influence of alcohol and persons who live at high altitudes are more affected by carbon monoxide than others. 

 

Early signs of carbon monoxide poisoning resemble the flu and include; headache, dizziness and/or nausea.  If you 

have these symptoms, the burner or  the appliance may not be installed or working properly, or the flue may be 

blocked.  GET  FRESH  AIR  AT  ONCE!  Verify  that  the  gas  log  set  is  properly  arranged  and  have  the  heater  and  

chimney flue serviced before using again.  

WARNING

 

During manufacturing, assembly and packaging, various components of this appliance are exposed to certain oils or 

films. These are not harmful but may produce annoying smoke and smells as they are burned off during the initial 

operation of the appliance, possibly causing headaches, eye or lung irritation. This is a normal occurrance and only 

temporary. The initial break-in operation should last 2-3 hours with the burner at the highest setting. Provide maximum 

ventilation by opening windows, doors and the chimney flue (if using a vented model) to allow odors to dissipate.  

The only odor remaining after this initial break-in period will be the normal odors associated with the combustion of 

Natural or Propane Gas and/or related to your indoor environment (see page 10). 

WARNING

Proposition 65 Statement 

 

If not installed, operated and maintained in accordance with these instructions, this product could expose you to 

substances in fuel or from fuel combustion which are known to the State of California to cause cancer,  

birth defects or other reproductive harm.

 

IMPORTANT INFORMATION 

 

• 

Due to high temperatures

, the appliance should be located out of traffic and away from furniture and draperies. 

• 

Children and adults 

should be alerted to the hazard of high surface temperatures and should stay away to avoid burns or 

clothing ignition. 

• 

Young children 

should be carefully supervised when they are in the same room with the appliance. 

• 

Do not place 

clothing or other flammable material on or near the appliance. 

• 

Any safety screen 

or guard removed for servicing an appliance must be replaced prior to operating the appliance. 

• 

Installation and repair 

should be done by a qualified service person. The appliance should be inspected before use and at 

least annually by a professional service person. More frequent cleaning may be required due to excessive lint from  
carpeting, bedding material etc. It is imperative that control compartments, burners and circulating air passageways of the  

appliance be kept clean. 

• 

WARNING: 

Any change to this appliance or its controls can be dangerous. 

• 

WARNING: 

Failure to keep the primary air opening(s) of the burner clean may result in sooting and property damage. 

• 

Keep appliance area 

clear and free from combustible materials, gasoline and other flammable vapors and liquids. 

• 

DO NOT 

use this room appliance if any part has been under water.  Immediately call a qualified service technician to  

    inspect the appliance and to replace any part of the control system and any gas control that has been under water. 

• 

WARNING: 

Before installing in a solid-fuel burning fireplace, the chimney flue and firebox must be cleaned of soot,  

creosote, ashes and loose paint by a qualified  chimney cleaner. 

• 

WARNING: 

Do not allow fans to blow directly into the fireplace.  Avoid any drafts that alter burner flame patterns. 

• 

WARNING: 

Do not use a blower insert, heat exchanger insert or any other accessory not approved for use with this heater. 

• 

A fireplace screen 

must be in place when the appliance is operating and, unless other provisions for combustion air are 

provided, the screen shall have an opening(s) for introduction of combustion air. 

• 

Solid fuels 

shall not be burned in a fireplace where this appliance is installed. 

• 

WARNING: 

Glass doors must be fully opened when appliance is in operation to allow for safe combustion, cooling of  

components and venting. 

• 

Any outside air ducts 

and/or ash dumps in the fireplace shall be permanently closed at the time of appliance installation. 

• 

This appliance may be used in sleeping quarters and bathrooms if used in a vented application, subject to local codes. 

• 

Avoid contact 

with the objects, chassis or another part which may be hot during operation. 

• 

RF-LD burner 

should 

not be installed 

in a Direct vent, B-Vent and or Vent free fireplace. 

• 

Log set is designed to 

burn with yellow flames

; thus 

adequate ventilation 

is absolutely necessary. 

Your gas log set is assembled at the factory to be installed in a fireplace plumbed with the gas supply on the right side 

(facing unit). DO NOT convert to the left side of burner. Instead, run a connecting pipe or aluminum flex connector  

(per local codes) behind burner along the back wall of fireplace bringing your gas line to the right side. 

Содержание RF-RF-LD30/36-VEI-N/P

Страница 1: ...ed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with type of gas indicated on the rating plate INSTALLER Leave this...

Страница 2: ...epair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to exc...

Страница 3: ...LD30 36 2 Rating I D Plate 3 Flex Connector SSCB 14 4 3 8 x 1 2 FIP Flared Brass Fitting A1 5 Orifice Spud see page 12 for size 6 Orifice Holder Internally Tapped 3 8 x 3 8 Flared MIP Fitting A2T 7 A...

Страница 4: ...Switch Cable GV60 SWA 24 Module Receiver GV60 RXA 29 8 Wire Cable GV60 C8 25 Interrupter Block GV60 TIA 30 GV60 Battery Box Cable GV60 BCA 26 Ignition Cable GV60 ICA 31 Plug in Adapter for AC Power Su...

Страница 5: ...and ventilation air must conform with The National Fuel Gas Code ANSI Z223 1 NFPA54 or The CSA B149 1 Natural Gas and Propane Installation Code latest edition STEP ONE PREPARATION 1 Verify that the Va...

Страница 6: ...E REQUIREMENTS The minimum permanent free opening of the fireplace chimney or chimney damper must be at least the minimum Chimney Area shown below based on a minimum chimney height of at least 8 feet...

Страница 7: ...propane gas burner A Natural Gas B Propane FIGURE 6 STEP TWO Sprinkle a light covering of Ember Magic over the Pan Medium Figure 6A and Figure 6B Pull apart Ember Magic fiber material to enhance the g...

Страница 8: ...charred burnt effect between the two halves Figure 8 and Figure 9 Place the Longest Log or 2 largest charred logs if applicable Figure 8A and 9A as far forward on the Grate as possible The remaining l...

Страница 9: ...ing BATTERY PACK PLACEMENT NOTE Any beeping or unexpected shutdown may be the over temperature safety feature in the receiver If this happens move the receiver into a cooler area and or use the RH2 RH...

Страница 10: ...ROL SETTINGS ON GAS VALVE WHILE OPERATING WITH REMOTE TRANSMITTER Valve switch set to 0 Valve switch set to I VALVE IN 0N POSITION Valve switch set to I Flame height control knob turned 0N Flame heigh...

Страница 11: ...beep release the reset button Within the subsequent 20 second press the small flame button on the handset until you hear two additional short beeps confirming the code is set If you hear one long bee...

Страница 12: ...k pilot flame Weak pilot flame is the NUMBER 1 SERVICE ISSUE REGARDING NUISANCE SHUT OFF Using canned compressed air blow out the opposing air intake ports located at the base of the pilot where the g...

Страница 13: ...l light properly The pilot flame should be steady and soft blue surrounding 1 8 inch of the thermocouple Pilot Tube Air Intake Port Thermocouple Tip Piezo Spark Blue Dot Natural Gas Red Dot Propane 1...

Страница 14: ...which have been closed or are obstructed with debris will not allow sufficient combustion air into the burner Use compressed air and or a soft bristle brush to clean the air mixer area Air mixers sho...

Страница 15: ...alve Vanisher Make sure the fireplace floor is even with the Hearth floor Also change batteries Odor and or Smoke After Break in Period other than Natural Odor of Gas Combustion Most likely causes Lac...

Страница 16: ...The maximum liability of RASMUSSEN in connection with this limited warranty shall not in any case exceed the contract price paid for the product claimed to be defective or unsuitable 4 This warranty...