ATTENTION! READ INSTRUCTIONS CAREFULLY BEFORE ASSEMBLY OR USE 

12028 E. PHILADELPHIA ST.  

WHITTIER, CA  CALIFORNIA  90601   U.S.A.  

www.rasmussen.biz 

WARNING 

This is a vented gas appliance for use only in a solid-fuel burning fireplace constructed on non-combustible material 

with a fully functional chimney flue which must vent all of the products of combustion.  

WHEN OPERATING, THE CHIMNEY DAMPER MUST BE FULLY OPEN  

Models; RF-LD 

30/36, 42/48, 60/72 

 VEI-Natural Gas (-N) or Propane (-P) 

18”        

Manzanita, LoneStar, CrossFire, Prestige Oak, Birch, Frosted Oak. 

20”/21” 

Evening Prestige, Evening Desire, Evening CrossFire, Evening Campfire, Evening LoneStar, CrossFire and  

             TimberFire 

24”       

Frosted Oak, Birch, Prestige Oak, CrossFire, LoneStar, Manzanita, TimberFire, Evening Lone Star, Evening  

             Prestige, Evening Desire, Evening CrossFire, Evening Campfire. 

30”       

Frosted Oak, Birch, Prestige Oak, CrossFire, LoneStar, Manzanita, TimberFire, Evening Lone Star, Evening  

             Prestige, Evening Desire, Evening CrossFire, Evening Campfire.

 

 

Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any other 

appliance. 

 

 

WHAT TO DO IF YOU SMELL GAS

 

• 

Do not try to light any appliance. 

• 

Do not touch any electrical switch; do not use 

any phone in your building. 

• 

Immediately call your gas supplier from a neigh-

bor’s phone. Follow the gas supplier’s 

 

instructions. 

• 

If you cannot reach your gas supplier, call the fire 

department.

 

 

 Installation and service must be performed by a  

qualified installer, service agency or the gas  

supplier

.

 

WARNING: If the information in this manual is not  

followed exactly, a fire or explosion may result caus-

ing property damage, personal injury or loss of life. 

This appliance may be installed in an aftermarket,  

permanently located, manufactured (mobile) home, 

where not prohibited by local codes.

 

 

This appliance is only for use with type of gas  

indicated on the rating plate.  

 

INSTALLER: Leave this manual with the appliance. 

CONSUMER: Retain this manual for future reference

Installation must conform with local codes or, in the  

absence of local codes, with the National Fuel Gas 

Code, ANSI Z223.1/NFPA 54. 

Improper installation, alteration, service or 

maintenance can cause property damage, personal 

injury or loss of life. Read these instructions 

thoroughly before installation. For assistance or 

additional information, consult your gas log dealer, 

qualified installer, service agency or gas supplier. 

In the Commonwealth of Massachusetts: 

• 

Installation must be performed by a licensed plumber or gas fitter. 

• 

The chimney flue damper, when used with gas logs, will be welded open or completely removed. 

• 

A CO detector shall be installed in the room where the appliance is installed. 

MINIMUM FIREPLACE FLUE REQUIREMENTS 

The minimum permanent free opening of the fireplace chimney or chimney damper must be at least the minimum 

chimney area shown on the chart on page 6, based on a minimum chimney height of at least 8 feet. The area of the flue 

must not be less than 1/10 the area of the fireplace opening. 

The flue must exhaust all products of combustion. 

WARNING: Failure to position the parts in accordance with the diagrams in this manual or failure to use only 

parts specifically approved with this appliance may result in property damage or personal injury. 

The installation and the provisions for combustion and ventilation air must conform with 

The National Fuel Gas 

Code ANSI Z223.1 / NFPA54

, or 

The CSA B149.1, Natural Gas and Propane Installation Code, 

latest edition.

 

RF-LD Multi-Burner 

 

DECORATIVE VENTED GAS LOG SET (Electric Ignition)

 

General Assembly, Installation, and Operation Instructions 

Owner’s Manual

 

Report #10-40 

Содержание RF-RF-LD30/36-VEI-N/P

Страница 1: ...ed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with type of gas indicated on the rating plate INSTALLER Leave this...

Страница 2: ...epair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to exc...

Страница 3: ...LD30 36 2 Rating I D Plate 3 Flex Connector SSCB 14 4 3 8 x 1 2 FIP Flared Brass Fitting A1 5 Orifice Spud see page 12 for size 6 Orifice Holder Internally Tapped 3 8 x 3 8 Flared MIP Fitting A2T 7 A...

Страница 4: ...Switch Cable GV60 SWA 24 Module Receiver GV60 RXA 29 8 Wire Cable GV60 C8 25 Interrupter Block GV60 TIA 30 GV60 Battery Box Cable GV60 BCA 26 Ignition Cable GV60 ICA 31 Plug in Adapter for AC Power Su...

Страница 5: ...and ventilation air must conform with The National Fuel Gas Code ANSI Z223 1 NFPA54 or The CSA B149 1 Natural Gas and Propane Installation Code latest edition STEP ONE PREPARATION 1 Verify that the Va...

Страница 6: ...E REQUIREMENTS The minimum permanent free opening of the fireplace chimney or chimney damper must be at least the minimum Chimney Area shown below based on a minimum chimney height of at least 8 feet...

Страница 7: ...propane gas burner A Natural Gas B Propane FIGURE 6 STEP TWO Sprinkle a light covering of Ember Magic over the Pan Medium Figure 6A and Figure 6B Pull apart Ember Magic fiber material to enhance the g...

Страница 8: ...charred burnt effect between the two halves Figure 8 and Figure 9 Place the Longest Log or 2 largest charred logs if applicable Figure 8A and 9A as far forward on the Grate as possible The remaining l...

Страница 9: ...ing BATTERY PACK PLACEMENT NOTE Any beeping or unexpected shutdown may be the over temperature safety feature in the receiver If this happens move the receiver into a cooler area and or use the RH2 RH...

Страница 10: ...ROL SETTINGS ON GAS VALVE WHILE OPERATING WITH REMOTE TRANSMITTER Valve switch set to 0 Valve switch set to I VALVE IN 0N POSITION Valve switch set to I Flame height control knob turned 0N Flame heigh...

Страница 11: ...beep release the reset button Within the subsequent 20 second press the small flame button on the handset until you hear two additional short beeps confirming the code is set If you hear one long bee...

Страница 12: ...k pilot flame Weak pilot flame is the NUMBER 1 SERVICE ISSUE REGARDING NUISANCE SHUT OFF Using canned compressed air blow out the opposing air intake ports located at the base of the pilot where the g...

Страница 13: ...l light properly The pilot flame should be steady and soft blue surrounding 1 8 inch of the thermocouple Pilot Tube Air Intake Port Thermocouple Tip Piezo Spark Blue Dot Natural Gas Red Dot Propane 1...

Страница 14: ...which have been closed or are obstructed with debris will not allow sufficient combustion air into the burner Use compressed air and or a soft bristle brush to clean the air mixer area Air mixers sho...

Страница 15: ...alve Vanisher Make sure the fireplace floor is even with the Hearth floor Also change batteries Odor and or Smoke After Break in Period other than Natural Odor of Gas Combustion Most likely causes Lac...

Страница 16: ...The maximum liability of RASMUSSEN in connection with this limited warranty shall not in any case exceed the contract price paid for the product claimed to be defective or unsuitable 4 This warranty...

Отзывы: