![Rasmussen K18-C1C-M-N Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/rasmussen/k18-c1c-m-n/k18-c1c-m-n_assembly-installation-and-operation-instructions_4072254008.webp)
ALL APPLICATIONS (VENTED and VENT FREE OPERATION)
DFC1 and DFC1C (Double Face) Log Placement (continued):
Front
Logs
v
.
Large
Top Log
.
v
Large
Top Log
.
v
v
.
.
v
v
v
v
Small
Top Logs
Small
Top Logs
v
v
v
v
Log
Grate
Guide
Figure 7
TOP VIEW
FRONT VIEW
Top Logs
Small
Front Log
Front Log
Top Logs
Small
Front Log
Top Logs
Small
Top Log
Large
Burner
Top Log
Large
Top Log
Large
Top Log
Large
Figure 8
WARNING: Failure to position parts in accordance with these diagrams
or failure to use only parts specifically approved with this heater may result in property
damage or personal injury.
LIGHTING AND OPERATION
C1A-M, C1C-M, C1B-M, C1D-M, DFC1-M and DFC1C-M (MANUAL CONTROL)
Rasmussen
Manufactured by:
Whittier, CA USA
Ignitor Button
Figure 9
Manual Valve Pilot Lighting, Operation, and Shutting Down:
1.
Slightly push in Valve Knob and turn to “S E A S O N O F F ”. Figure 10
2. Before lighting, wait at least five minutes (10 minutes for LP gas) to
allow gas which may have accumulated around burner to escape.
3.
Slightly push in Valve Knob and turn to “P I L O T / O F F ”. Figure 10
4.
Depress Valve Knob until air is bled and gas flows to pilot. Press
PIEZO IGNITOR Button (Figure 9) to light pilot. Continue to hold
valve knob in until Pilot remains lit when knob is released.
5.
Slowly turn knob to “O N ”. The rear burner will light from the pilot. The
front burner will light from the carry-over tube.
6.
If appliance fails to light or if pilot goes out, repeat steps 1 through 5 .
7.
For complete shutdown, push knob in and turn to “SEASON OFF”.
Pilot
Access
Port
AT PILOT POSITION
SLIGHT PUSH TO
TURN OFF
FULL PUSH TO
LIGHT
OFF ON
. . .
Valve Knob
Figure 10
C1A, C1C, C1B, C1D, DFC1 and DFC1C-S/R (SWITCH or REMOTE CONTROL)
Millivolt Valve Pilot Lighting:
1.
Depress and turn Gas Cock Dial to "OFF" position. (see Figure 12)
2.
Place the Control Selector Switch ("S" models-Figure 11) or the Remote
Receiver Switch ("R" models-Figure 13) into the O F F position. Place any Accessory
Controls (Remote Control, Wall Switch or Wall Timer) to "OFF". Place Wall Thermostat to
lowest temperature setting or Off.
3.
Wait at least 5 minutes to allow gas which may have accumulated around burner to escape.
4.
Depress and turn Gas Cock Dial to "PILOT" position.
5.
Depress and hold Gas Cock Dial until air is bled and gas flows to pilot.
SELECTOR SWITCH
Figure 11
SWITCH OFF REMOTE
ON ACCESS
ON
8