ALL APPLICATIONS (VENTED and VENT FREE OPERATION)

9.  The CHILLBUSTER and its individual shutoff valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). The CHILLBUSTER must
be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing
of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
10. The area around the CHILLBUSTER must be clear and free from combustible materials, gasoline and any other
flammable vapors and liquids. Provide adequate clearances for servicing and proper operation.
11. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system and any gas control which has been under water.

IMPORTANT SAFEGUARDS

This appliance is for supplemental heating

only. It should not be used as the primary heat
source for a dwelling.

WARNING: During manufacturing, fabricating, and

shipping, various components of CHILLBUSTER are
treated with certain oils or films. These are not harmful but
may produce annoying smoke and smells as they are
burned off during the initial operation of the appliance,
possibly causing headaches or eye or lung irritation. This
is a normal and temporary occurrence. The initial break-in
operation should last 2-3 hours with the burner at the
highest setting. Provide maximum ventilation by opening
windows, doors, and the chimney flue to allow odors to
dissipate. The only odor remaining after this initial break-in
will be the normal odors associated with the combustion
of Natural or Propane gas.

This appliance is equipped with an ODS (OXYGEN

DEPLETION SENSOR) pilot light safety system designed
to shut itself off if not enough fresh air is available.
Additional ventilation may be obtained by opening a
window or a door to another room.

Although your CHILLBUSTER is very realistic in

appearance, it is not a real wood burning fireplace.
Matches, paper, garbage, or any other material must not
be thrown on top of the logs or into the flames.

Avoid contact with the logs, grate, or any other part

which may be hot.

Always ensure that the fireplace screen is closed

when the appliance is operating.

State or local codes may only allow operation of this

appliance in a vented configuration. Check your state or
local codes. If not permitted, you may install and operate
CHILLBUSTER as a vented appliance. (See " V E N T E D
OPERATION" 
below).

WARNING: Before installing in a solid fuel burning fireplace,

the chimney flue and firebox must be cleaned of soot, creosote, ashes

and loose paint by a qualified chimney cleaner.

WARNING: Do not allow fans to blow directly into the fireplace.  Avoid

any drafts that alter burner flame patterns.

WARNING: Do not use a blower insert, heat exchanger insert or

other accessory not approved for use with this heater.

PREPARATION OF FIREPLACE

1.

Ensure firebox and chimney damper/flue are
thoroughly cleaned (if previously used for either gas
or wood burning.) Failure to adequately clean
firebox, damper and flue may cause fumes,

 

sooting and/or fire.

2.

If local valve is not already installed, install a gas valve 
on the supply line in or just outside the fireplace.

3.

Any outside air ducts and/or ash dumps in the
fireplace shall be permanently closed at time of
installation of this CHILLBUSTER.

4.

Use Propane Gas resistant compound on all pipe
fittings (not on connections with flared fitting).

5.

Test new piping for leaks using soap solution. 
Do not use open flame to flame test.

All Soot Must Be Completely Removed From Firebox Prior To Installing!

VENTED OPERATION

Damper Stop
Clamp

Damper

Chimney
Flue

VENTED APPLICATION

1.  The minimum permanent free opening of the fireplace

chimney or chimney damper must be at least 2 9  sq. inches
based upon a minimum chimney height of at least 10 feet.

2.

The  chimney damper must be fixed in a manner to maintain
permanent free opening as (outlined in item above) at all times.
To accomplish this, install the damper clamp (provided) on the
edge of the damper blade to prevent its closing, or drill holes in
the damper

   .

3

Содержание K18-C1C-M-N

Страница 1: ...sted ventless firebox enclosure DO NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs WARNIN...

Страница 2: ...a CHILLBUSTER is installed 3 The minimum size in inches of the fireplace in which this CHILLBUSTER is to be installed must be as follows SET SIZE MODEL NUMBER FRONT WIDTH HEIGHT DEPTH 18 24 30 18 24...

Страница 3: ...USTER is very realistic in appearance it is not a real wood burning fireplace Matches paper garbage or any other material must not be thrown on top of the logs or into the flames Avoid contact with th...

Страница 4: ...table Btu Hr 72 000 Btu Hr Actual Btu Hr Used 11 840 Btu Hr Excess Non Supportable Btu Hr In the example because the Actual Btu Hr Used exceeds the Maximum Supportable Btu hr the space would be consid...

Страница 5: ...bing electrical and gas lines and at other openings WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH When used without fresh air gas log sets may give off carbon monoxide an odorless colorless pois...

Страница 6: ...OX Figure 3 4 Standard Fireplace Hood with a minimum 4 inch horizontal projection beyond vertical surface ABOVE hood as provided by most major fireplace manufacturers IF YOU CANNOT MEET THESE MINIMUM...

Страница 7: ...VIEW FRONT VIEW Front Log Rear Log Top Log Large R Top Log Large L Top Log Small L Top Log Small R Front Log Rear Log Top Log Large R Top Log Small R Top Log Large L Top Log Small L Main burner 24 30...

Страница 8: ...Valve Knob until air is bled and gas flows to pilot Press PIEZO IGNITOR Button Figure 9 to light pilot Continue to hold valve knob in until Pilot remains lit when knob is released 5 Slowly turn knob t...

Страница 9: ...ared and operate instantly and requires you to aim and hold the transmitter for 1 to 3 seconds to operate Manual Operation Receiver switch position ON or OFF does not require batteries Remote Operatio...

Страница 10: ...the area around the CHILLBUSTER free and clear from debris From time to time visually check pilot and burner flames for proper appearance Figures 15 and 16 Normal flame color should be yellow body sur...

Страница 11: ...20 21 22 24 26 31 30 23 25 2 8 32 33 40 41 42 43 50 51 60 61 62 1 O22 Burner 40 000 BTU or 9 Push Button Ignitor DFC1 C1C Double Face 43 Valve Knob O38 Burner 23 000 BTU 10 Inlet Aluminum Connector 30...

Страница 12: ...as set forth herein and applies only for the periods designated above 2 RASMUSSEN shall not be liable for any loss damage incidental or consequential damages of any kind whether based upon warranty c...

Страница 13: ...CPW CB 2 96 CHANGES next page 1 standard update z21 11 2a 2001 DUE 4 03 standard update z21 11 2b 2002 DUE 12 03 13...

Отзывы: