ALL APPLICATIONS (VENTED and VENT FREE OPERATION)

IMPORTANT NOTICE

Due to high temperatures, the appliance should be located out of traffic and away from
furniture and draperies.

Children and adults should be alerted to the hazard of high surface temperature and should
stay away to avoid burns or clothing ignition.

Young children should be carefully supervised when they are in the same room with the
appliance.

"WARNING: Any change to this heater or its controls can be dangerous."

Do not place clothing or any other flammable material on or near the appliance.

Any safety screen or guard removed for servicing an appliance must be replaced prior to
operating the heater.

Installation and repair should be done by a qualified service person. The appliance should
be inspected before use and at least annually by a professional service person. More
frequent cleaning may be required due to excessive lint from carpeting, bedding material,
etc. It is imperative that control compartments, burners and circulating air passageways of
the appliance be kept clean.

"WARNING: Failure to keep the primary air opening(s) of the burner(s)

clean may result in sooting or property damage."

Do not use this CHILLBUSTER as a Vent Free Heater in sleeping quarters, bathrooms or
recreational vehicles.

Keep burner and control compartment clean. See page 10 of these instructions.

Any outside air ducts in the fireplace shall be permanently closed at time of installation.

This appliance may be installed in an after market, permanently located, manufactured 

(mobile) home, where not prohibited by local codes.

This appliance is for use with the type of gas indicated on the rating plate. This appliance is
not convertible for use with other gases.

   .

IMPORTANT INFORMATION

1.

This CHILLBUSTER is for installation only in a solid-fuel burning fireplace or listed ventless firebox enclosure.

2.

Solid fuels shall not be burned in a masonry or UL 127 factory builtfireplace where a CHILLBUSTER is installed.

3.

The minimum size (in inches) of the fireplace in which this CHILLBUSTER is to be installed must be as follows:

S E T

S I Z E

M O D E L

NUMBER

FRONT
WIDTH

HEIGHT

D E P T H

18
24
30
18
24
30
18
24
30
18
24
30

(K,W,KW)(18)-C1C-(M, S, R)-(N,P) 23,000 BTU/HR
(K,W,KW)(24)-C1C-(M, S, R)-(N,P) 23,000 BTU/HR
(K,W,KW)(30)-C1D-(M, S, R)-(N,P) 23,000 BTU/HR
(K,W,KW)(18)-C1A-(M, S, R)-(N,P) 40,000 BTU/HR
(K,W,KW)(24)-C1A-(M, S, R)-(N,P) 40,000 BTU/HR
(K,W,KW)(30)-C1B-(M, S, R)-(N,P) 40,000 BTU/HR

DF(K,W,C)(18)-DFC1C-(M, S, R)-(N,P) 23,000 BTU/HR
DF(K,W,C)(24)-DFC1C-(M, S, R)-(N,P) 23,000 BTU/HR
DF(K,W,C)(30)-DFC1C-(M, S, R)-(N,P) 23,000 BTU/HR

DF(K,W,C)(18)-DFC1-(M, S, R)-(N,P) 40,000 BTU/HR
DF(K,W,C)(24)-DFC1-(M, S, R)-(N,P) 40,000 BTU/HR
DF(K,W,C)(30)-DFC1-(M, S, R)-(N,P) 40,000 BTU/HR

24
30
36
24
30
36
24
30
36
24
30
36

17
17
17
17
17
17
17
17
17
17
17
17

11
11
11
11
11
11
16
16
16
16
16
16

4.  When operated as a VENT FREE heater, the minimum clearances from the fireplace opening to combustible
materials must be maintained as outlined in section "CLEARANCES TO COMBUSTIBLES" (page 5).
5.

A fireplace screen must be in place when the CHILLBUSTER is in operation and, unless other provisions for

combustion air are provided, the screen shall have opening(s) for introduction of combustion air. Glass doors are not
certified with the CHILLBUSTER. However, if used, Glass Doors must be wide open when the burner is on
to allow air for safe combustion, cooling of components and venting. Adequate clearances must be provided around
fireplace opening for adequate combustion and proper operation.
6.

The minimum inlet gas supply pressure for the purpose of input adjustment shall be 5 inches of water column on

natural gas and 11 inches of water column on Propane gases.
7.

The maximum inlet gas supply pressure shall be 7 inches of water column on natural gas and 14 inches of water

column  on Propane gases. The Propane source must be regulated. Never connect CHILLBUSTER directly to an
unregulated Propane tank.
8.

The installation and the provision for combustion and ventilation air must conform with the National Fuel Gas Code

ANSI Z223.1 latest edition. S e e   "

PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR"

(pages 4 and 5).

2

Содержание K18-C1C-M-N

Страница 1: ...sted ventless firebox enclosure DO NOT install this appliance in a factory built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs WARNIN...

Страница 2: ...a CHILLBUSTER is installed 3 The minimum size in inches of the fireplace in which this CHILLBUSTER is to be installed must be as follows SET SIZE MODEL NUMBER FRONT WIDTH HEIGHT DEPTH 18 24 30 18 24...

Страница 3: ...USTER is very realistic in appearance it is not a real wood burning fireplace Matches paper garbage or any other material must not be thrown on top of the logs or into the flames Avoid contact with th...

Страница 4: ...table Btu Hr 72 000 Btu Hr Actual Btu Hr Used 11 840 Btu Hr Excess Non Supportable Btu Hr In the example because the Actual Btu Hr Used exceeds the Maximum Supportable Btu hr the space would be consid...

Страница 5: ...bing electrical and gas lines and at other openings WARNING CARBON MONOXIDE POISONING MAY LEAD TO DEATH When used without fresh air gas log sets may give off carbon monoxide an odorless colorless pois...

Страница 6: ...OX Figure 3 4 Standard Fireplace Hood with a minimum 4 inch horizontal projection beyond vertical surface ABOVE hood as provided by most major fireplace manufacturers IF YOU CANNOT MEET THESE MINIMUM...

Страница 7: ...VIEW FRONT VIEW Front Log Rear Log Top Log Large R Top Log Large L Top Log Small L Top Log Small R Front Log Rear Log Top Log Large R Top Log Small R Top Log Large L Top Log Small L Main burner 24 30...

Страница 8: ...Valve Knob until air is bled and gas flows to pilot Press PIEZO IGNITOR Button Figure 9 to light pilot Continue to hold valve knob in until Pilot remains lit when knob is released 5 Slowly turn knob t...

Страница 9: ...ared and operate instantly and requires you to aim and hold the transmitter for 1 to 3 seconds to operate Manual Operation Receiver switch position ON or OFF does not require batteries Remote Operatio...

Страница 10: ...the area around the CHILLBUSTER free and clear from debris From time to time visually check pilot and burner flames for proper appearance Figures 15 and 16 Normal flame color should be yellow body sur...

Страница 11: ...20 21 22 24 26 31 30 23 25 2 8 32 33 40 41 42 43 50 51 60 61 62 1 O22 Burner 40 000 BTU or 9 Push Button Ignitor DFC1 C1C Double Face 43 Valve Knob O38 Burner 23 000 BTU 10 Inlet Aluminum Connector 30...

Страница 12: ...as set forth herein and applies only for the periods designated above 2 RASMUSSEN shall not be liable for any loss damage incidental or consequential damages of any kind whether based upon warranty c...

Страница 13: ...CPW CB 2 96 CHANGES next page 1 standard update z21 11 2a 2001 DUE 4 03 standard update z21 11 2b 2002 DUE 12 03 13...

Отзывы: