ALL APPLICATIONS (VENTED and VENT FREE OPERATION)
LIGHTING and OPERATION
Control Locations and Description
All Models (C9-S-R)
•
Primary Gas Valve Control Knob (Switch
Models):
Pilot Lighting and Valve gas output
adjustment from OFF to FULL.
See Figure 7
•
Switch Models (C9-S) 3 Way Selector Switch:
Mode selections: SWITCH ON, OFF REMOTE
ACCESS ON.
See Figure 6.
•
Switch Models (C9-S) Piezo Ignitor Button:
Pilot Flame Ignition.
Figure 4
3 WAY SELECTOR SWITCH
(Switch Models Only)
PIEZO IGNITER
BUTTON
Pilot Position
PRIMARY GAS VALVE
CONTROL KNOB
C9-S (Switch Control) LIGHTING and OPERATION
Pilot Lighting:
1. Depress and turn the
Primary Gas Valve Control Knob
(located at the base of the right
rear grate leg, clockwise to the
"OFF"
position.
See Figures 4 and 7.
2. Place the
3 Way
Control Selector Switch
in
OFF (Fig 6)
. Turn off all Remote
Accessory Controls (Switch or Hand Held Remote) or place Thermostat to lowest setting.
3. Wait at least 5 minutes prior to lighting
4. Depress and turn
Primary Gas Valve Control Knob
counter clockwise to the
"PILOT"
position. (
Figure 7
)
SWITCH OFF REMOTE
ON ACCESS
ON
3 WAY CONTROL
SELECTOR SWITCH
Figure 6
5. Depress fully and hold in the
Primary
Gas Valve Control Knob
until all air is
bled and gas flows to pilot.
6. Press
Piezo Ignitor Button
(Figure 3) to light pilot. Continue to hold
in
Primary Gas Valve Control
Knob
until the Pilot flame remains lit when knob
is released (approx 60 to 90 seconds). If
Pilot does not remain lit, repeat steps
1.
through
5.
and allow additional time after
Figure 7
"ON" POSITION
+
+
v
+
+
PILOT
+
v
+
+
PILOT ADJUST COVER CAP
lighting Pilot before releasing knob.
Switch Control (Manual ON-OFF):
After successful pilot lighting, allow 60-90 seconds for the Thermogenerator to heat up. To turn burner on, place
Control Selector Switch
in the
"ON"
position (
see Figure 6
). To turn burner off (pilot remains lit) place
Control Selector Switch
in the
"OFF"
position.
NOTE: Flame size at the burner is adjustable at the
Primary Gas Valve Control
Knob
(
see Figure 7
).
Shutdown
:
For complete shutdown (including Pilot), place
Control Selector Switch
in the
"OFF"
position
and push
Primary Gas Valve Control
Knob (Fig 7)
in and turn fully clockwise to “
OFF
”.
Switch Accessory Wiring:
Wiring from the Accessory Control (Remote, Thermostat or
Switch) is connected to the two
outside terminals
of the
Control Selector Switch
as shown.
NOTE:
Wire length for Thermostat or Remote or controls
should not exceed 20 feet. Thermostat wiring should be 20
AWG Type CL2.
Switch Accessory Operation:
Place manual switch in the
"
REMOTE ACCESS ON
" position. Burner "
ON
" or "
OFF
" is
now controlled by the position of the accessory control being
used with the burner.
From THERMOPILE
Valve
Terminals
3 Way Control Selector Switch
To ACCESSORY CONTROL
Outside
Terminal
Piggy
Back
Outside
Terminal