This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is 
installed. Provisions for adequate combustion and ventilation air must be provided. Refer 
to Section "PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR" (pages 
4 and 5.)

.

 

 

ALL APPLICATIONS (INSTALLATION)

 

 

ALL APPLICATIONS-IMPORTANT NOTICE 

• 

Children and adults should be alerted to the hazard of high surface temperature and should stay away to 

 

avoidburns or clothing ignition. 

• 

Young children should be carefully supervised when they are in the same room with the appliance. 

• 

Do not place clothing or any other flammable material on or near the appliance. 

• 

Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the heater. 

• 

WARNING:

 During manufacturing, fabricating, and shipping, various components of CHILLBUSTER are 

 

treated with certain oils or films. These are not harmful but may produce annoying smoke and smells as they are 

 

burned off during the initial operation of the appliance, possibly causing headaches or eye or lung irritation. This 

 

is a normal and temporary occurrence. The initial break-in operation should last 2-3 hours with the burner at the 

 

highest setting. Provide maximum ventilation by opening windows, doors, and the chimney flue to allow odors to 

 

dissipate. The only odor remaining after this initial break-in will be the normal odors associated with the 

 

combustion of Natural or Propane gas. 

• 

This appliance is equipped with an ODS (OXYGEN DEPLETION SENSOR) pilot light safety system designed to 

 

shut itself off if not enough fresh air is available. Additional ventilation may be obtained by opening a window or a 

 

door to another room. 

• 

Although your CHILLBUSTER is very realistic in appearance, it is not a real wood burning fireplace. Matches, 

 

paper, garbage, or any other material must not be thrown on top of the logs or into the flames. 

• 

Avoid contact with the logs, grate, or any other part which may be hot. 

• 

Always ensure that the fireplace screen is closed when the appliance is operating.

.

 

 

ALL APPLICATIONS-IMPORTANT INSTALLATION INFORMATION

 

 

 

WARNING: Design certified for installation only in a  solid-fuel burning masonry or 
UL 127 factory-built  fireplace or in a listed ventless firebox enclosure.  It has been 
design certified for these installations.  DO NOT install this appliance in a factory-
built fireplace that includes instructions stating it has not been tested or should not 
be used with unvented gas logs. 

 
 

"WARNING: Any change to this heater or its controls can be dangerous." 

 

 

Installation and repair should be done by a qualified service person. The appliance should be 
inspected before use and at least annually by a professional service person.  
More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It 
is imperative that control compartments, burners and circulating air passageways of the appliance 
be kept clean. 

 

 

State or local codes may only allow operation of this appliance in a vented configuration. Check your 
state or local codes. If not permitted, you may install and operate CHILLBUSTER as a vented 
appliance. (See "VENTED OPERATION" page 3). 

 
 

This appliance is for supplemental heating only. It should not be used as the primary heat source for 
a dwelling. 

 
 

Due to high temperatures, the appliance should be located out of traffic and away from furniture and 
draperies.

 

 

 

"WARNING: Failure to keep the primary air opening(s) of the burner(s)clean may 

result in sooting or property damage."  

 

1.  This appliance may be installed in an after market, permanently located, manufactured (mobile) home, where not 
 

prohibited by local codes. 

Содержание Chillbuster CL-11-C9A-ME

Страница 1: ...use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the information in this manual is not followed exactly a fire or explosion may result caus ing...

Страница 2: ...s very realistic in appearance it is not a real wood burning fireplace Matches paper garbage or any other material must not be thrown on top of the logs or into the flames Avoid contact with the logs grate or any other part which may be hot Always ensure that the fireplace screen is closed when the appliance is operating ALL APPLICATIONS IMPORTANT INSTALLATION INFORMATION WARNING Design certified ...

Страница 3: ...djustment shall be 5 inches of water column The maximum inlet gas supply pressure shall be 7 inches of water column 2 Propane Gas The minimum inlet gas supply pressure for the purpose of input adjustment shall be 11 inches of water column The maximum inlet gas supply pressure shall be 14 inches of water column The Propane source must be regulated Never connect CHILLBUSTER directly to an unregulate...

Страница 4: ...The National Fuel Gas Code defines a confined space as a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8m3 per kW of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1 000 Btu per hour 4 8m3 per kW of the aggregate input rating of all appliances installed in that space Ro...

Страница 5: ...red an Unconfined Space No additional fresh combustion and ventilation air would be required VENT FREE OPERATION COMBUSTION AIR CALCULATIONS WORKSHEET 1 Room Width Length Height W x L x H Vol ft3 1a 1b 1c 1d 2 Total Volume ft3 sum of Volume ft3 of all rooms sum lines 1a thru 1d 2 3 Max Supportable BTu Hr Total Volume ft3 50 x 1000 line 2 50 x1000 3 4 4a 3 Btu hr 4b 3 Btu hr 4c 3 Btu hr 4d 3 Btu hr...

Страница 6: ... from top of fireplace opening Mantel See Charts and Diagrams shown at Figures 1 and 2 NOTE Clearances to Combustible Construction are those distances required to ensure that a fireplace mantel or facing will not catch fire In most cases they should also be adequate to prevent any discoloration or warping due to heat However each and every Gas Log Installation CHILLBUSTER included presents a diffe...

Страница 7: ...F YOU CANNOT MEET THESE MINIMUM CLEARANCES YOU MUST OPERATE HEATER WITH CHIMNEY FLUE DAMPER OPEN Operate as a VENTED Heater See Page Three ALL APPLICATIONS VENTED and VENT FREE OPERATION ASSEMBLY AND INSTALLATION WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injur...

Страница 8: ...and REAR BOTTOM COALS Place BOTTOM COALS C9A 4 coal array C9B 5 coal array into Stainless Steel Lifters and center 2 TOP COALS Place TOP COALS C9A 3 coal array C9B 4 coal array on top and between BOTTOM COALS and center Volcanic Ash Placement Place VOLCANIC ASH only on the firebox floor DO NOT PLACE VOLCANIC ASH or any other material ON TOP OF BURNER ...

Страница 9: ...t Continue to hold in Primary Gas Valve Control Knob until the Pilot flame remains lit when knob is released approx 60 to 90 seconds If Pilot does not remain lit repeat steps 1 through 5 and allow additional time after Figure 7 ON POSITION v PILOT v PILOT ADJUST COVER CAP lighting Pilot before releasing knob Switch Control Manual ON OFF After successful pilot lighting allow 60 90 seconds for the T...

Страница 10: ...ceiver switch to OFF C9 R Remote Control LIGHTING and OPERATION Pilot Lighting Remote Operated Valve NOTE The Operating Dial has complete control of gas to pilot and burner The Operating Dial cannot be turned to OFF without first depressing dial in PILOT position and then rotating clockwise to OFF see Figure 8 1 Depress and turn Operating Dial to OFF position Fig 8 2 Wait at least 5 minutes to all...

Страница 11: ...E RE NUISANCE SHUT OFF Using canned compressed air pipe cleaner or an artist s brush clean out the opposing Air Intake Ports located at base of Pilot where gas supply line attaches to pilot Figure 9 ALL APPLICATIONS VENTED and VENT FREE OPERATION NORMAL OPERATING CHARACTERISTICS Each and every CHILLBUSTER that leaves the factory is quality checked to ensure compliance with our American Gas Associa...

Страница 12: ... also be thoroughly cleaned of all burn residue and soot using a damp cloth sponge or brush Do not operate this set with any logs other than the RASMUSSEN CHILLBUSTER Refractory Logs specifically designed and approved for use with this Burner System Do not use with blower inserts or heat exchangers If used glass doors must be wide open when burner is on Do not remove Rating Plate Warning Tags Thes...

Страница 13: ...C9B 6 1 4 Front Burner Gas 12 Heat Shield 30 Remote Valve 2 Bottom Coal Array 2 Supply Connector 13 Grate 31 Remote Receiver 4 coal C9a 5 coal C9B 7 Rear Burner 32 Remote transmitter 3 3 8 Gas Supply 8 Front Burner C9 S Switch Connector 9 ODS Pilot N or LP 20 MV Valve 5 0 or 10 0 4 1 4 Rear Burner Gas MV or Standard 21 3 Way Switch S Model Supply Connector 10 Rear Burner Orifice Holder 22 Piezo ...

Страница 14: ...ARRANTY The following warranty has been drafted to comply with the MAGNUSON MOSS WARRANTY ACT applicable to products manufactured after July 4 1975 It replaces and supersedes any warranty in this package or in any printed literature ...

Страница 15: ...idental or consequential damages of any kind whether based upon warranty contract or negligence arising in connection with the sale use or repair of the product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you 3 The maximum liability of RASMUSSEN in connection with this limited warranty shall not i...

Отзывы: