Rasilient Confidential
- Use or disclosure of data contained on this page is subject to the restriction on the title page
of this document.
vi
Environmental Specification
Temperature and Temperature Gradient
Operating
Ambient Temperature
5 to 35ºC
Max Temperature Gradient
20ºC per hour
Non-Operating
Ambient Non-Operating
-40 to 60 ºC
Humidity
Operating
Ambient Operating (Non-
condensing)
8 to 85 % R.H
Non-Operating
Ambient Non-Operating (Non-
condensing)
8 to 95 % R.H
Altitude
Operating
3050m (support for up to 3050m requires temperature de-rating) [950m@
35
℃
, 3050m@ 28
℃
]
NOTE
: De-rate max operating temperature 1 ºC /300m above 950m
altitude.
Non-Operating
Maximum Altitude of 12,000 meters (39,370 feet)
Cooling specification
The thermal solution supports drive up to 13 W maximum power dissipation per drive slot.
● Fan failure:
System can keep normal operation when one of two fans in the fan
module failed. System fan module replacement maximum time is 10
minutes.
● Drive failure:
The cooling system will ensure that the system continues while the top cover is
removed for drive failure.
Drive replacement maximum time is 10 minutes.
● PSU failure:
The system can operate during a PSU replacement service interval of 10 minutes without
experiencing an over temperature condition in the canister.