WIRING
5
Table 4- Pressurized Freshwater Model
Table 3- Sea Water Model(sizes based on both inlet and discharge amps added)
SEAERA QC MODEL 162
Table 5 - Remote Intake Pump Only
Table 2- Pressurized Freshwater Model
Table 1-Sea Water Model (sizes based on both inlet and discharge amps added)
ATLANTES FREEDOM VORTEX VAC AND MARINE ELEGANCE
Recommended Wire and Fuse/Circuit Breaker Sizes
Units
Voltage
Circuit
Breaker/
fuse size
(amps)
Toilet
Discharge
Amps draw
Remote
Pump
Only Amp
draw
10 feet
15 feet
20 feet
30 feet
40 feet
50 feet
12 VDC
30
18
10
10 AWG
8 AWG
6 AWG
4 AWG
4 AWG
2 AWG
24 VDC
20
10
5
16 AWG
14 AWG
12 AWG
12 AWG
10 AWG
8 AWG
Units
Voltage
Circuit
Breaker/fuse
size (amps)
Amp draw
10 feet
15 feet
20 feet
30 feet
40 feet
50 feet
12 VDC
25
18
10 AWG
10 AWG
8 AWG
6 AWG
6 AWG
4 AWG
24 VDC
15
10
16 AWG
16 AWG
14 AWG
12 AWG
10 AWG
10 AWG
Units
Voltage
Circuit
Breaker/
fuse size
(amps)
Toilet
Discharge
Amps draw
Remote
Pump Only
Amp draw
10 feet
15 feet
20 feet
30 feet
40 feet
50 feet
12 VDC
25
13
10
10 AWG
8 AWG
6 AWG
6 AWG
4 AWG
4 AWG
24VDC
15
7.5
5
16 AWG
14 AWG
12 AWG
10 AWG
10 AWG
8 AWG
Units
Voltage
Circuit
Breaker/fuse
size (amps)
Amp draw
10 feet
15 feet
20 feet
30 feet
40 feet
50 feet
12 VDC
25
13
12 AWG
10 AWG
10 AWG
8 AWG
6 AWG
6 AWG
24 VDC
15
7.5
16 AWG
16 AWG
14 AWG
12 AWG
10 AWG
10 AWG
Units
Voltage
Circuit
Breaker/fuse
size (amps)
Amp draw
10 feet
15 feet
20 feet
30 feet
40 feet
50 feet
12 VDC
15
10
14 AWG
12 AWG
10 AWG
10 AWG
8 AWG
6 AWG
24 VDC
10
5
16 AWG
16 AWG
16 AWG
16 AWG
14 AWG
12 AWG
L480 0216jlc